콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

T39853

Sigma-Aldrich

Tolylene-2,4-diisocyanate

95%

동의어(들):

2,4-Diisocyanatotoluene, 4-Methyl-1,3-phenylene diisocyanate, 4-Methyl-m-phenylene diisocyanate, BASF LUPRANATE T80, TDI

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
CH3C6H3(NCO)2
CAS Number:
Molecular Weight:
174.16
Beilstein:
744602
EC Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

vapor density

6 (vs air)

vapor pressure

0.03 mmHg ( 25 °C)

분석

95%

autoignition temp.

>1148 °F

expl. lim.

9.5 %

불순물

4% 2,6-isomer

refractive index

n20/D 1.568 (lit.)

bp

115-120 °C/10 mmHg (lit.)

mp

20-22 °C (lit.)

density

1.214 g/mL at 25 °C

저장 온도

2-8°C

SMILES string

Cc1ccc(cc1N=C=O)N=C=O

InChI

1S/C9H6N2O2/c1-7-2-3-8(10-5-12)4-9(7)11-6-13/h2-4H,1H3

InChI key

DVKJHBMWWAPEIU-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Employed in the preparation of polyurethanes and macrocyclic crown ethers.

픽토그램

Skull and crossbonesHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 1 Inhalation - Aquatic Chronic 3 - Carc. 2 - Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 2

Flash Point (°F)

269.6 °F - closed cup

Flash Point (°C)

132 °C - closed cup

개인 보호 장비

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

R S Labow et al.
Biomaterials, 16(1), 51-59 (1995-01-01)
The biostability of polyurethanes was evaluated using a human neutrophil cell culture. The polymers were synthesized with 14C radiolabelled components incorporated into the polyurethane chain and the amount of radiolabel released during exposure to cells and medium was used as
J. Incl. Phenom. Mol. Recog. Chem., 17, 249-249 (1994)
Olov Collste et al.
Journal of cardiac failure, 20(12), 968-972 (2014-10-01)
Our objective was to investigate whether dobutamine stress echocardiography (DSE) could induce abnormal cardiac function in takotsubo stress cardiomyopathy (TSC) patients in a stable condition after the acute attack. This was a case-control study and a substudy of the Stockholm
Tatiana Kuznetsova et al.
American journal of hypertension, 28(4), 535-545 (2014-09-23)
The cardio-renal interaction occurs via hemodynamic and humoral factors. Noninvasive assessment of renal hemodynamics is currently possible by assessment of renal resistive index (RRI) derived from intrarenal Doppler arterial waveforms as ((peak systolic velocity - end-diastolic velocity)/peak systolic velocity). Limited
Norman Mangner et al.
JACC. Cardiovascular imaging, 7(12), 1198-1205 (2014-10-13)
The aim of our study was to assess geometric and functional changes of the heart in obese compared with nonobese children and adolescents. Obesity in children and adolescents has increased over the past decades and is considered a strong risk

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.