콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

D83532

Sigma-Aldrich

Diethoxydiphenylsilane

97%

동의어(들):

Diphenyldiethoxysilane

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
(C6H5)2Si(OC2H5)2
CAS Number:
Molecular Weight:
272.41
Beilstein:
2281302
EC Number:
MDL number:
UNSPSC 코드:
12352103
PubChem Substance ID:
NACRES:
NA.23

분석

97%

양식

liquid

refractive index

n20/D 1.525 (lit.)

bp

167 °C/15 mmHg (lit.)

density

1.033 g/mL at 25 °C (lit.)

SMILES string

CCO[Si](OCC)(c1ccccc1)c2ccccc2

InChI

1S/C16H20O2Si/c1-3-17-19(18-4-2,15-11-7-5-8-12-15)16-13-9-6-10-14-16/h5-14H,3-4H2,1-2H3

InChI key

ZZNQQQWFKKTOSD-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

A new diethoxydiphenylsilane based solid-phase microextraction fiber was developed to extract trace levels of polycyclic aromatic hydrocarbons in millk, {48} human urine.{49} Diethoxydiphenylsilane based coating can be used to detect explosives (2,4,5-trinitrotoulene, 2,4-dinitrotoluene, 2,4-dinitrotoluence) and explosive taggants (ethylene glycol dinitrate).{50} This alkylsilylation reagent may be used for surface modification of nanoporous rice husk silica (RHS).{51}

픽토그램

Exclamation mark

신호어

Warning

유해 및 위험 성명서

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

표적 기관

Respiratory system

Storage Class Code

10 - Combustible liquids

WGK

WGK 3

Flash Point (°F)

230.0 °F - closed cup

Flash Point (°C)

110 °C - closed cup

개인 보호 장비

Eyeshields, Gloves, type ABEK (EN14387) respirator filter


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

A Study on Modification of Nanoporous Rice Husk Silica for Hydrophobic Nano Filter.
Kim HJ, et al.
Journal of Nanoscience and Nanotechnology, 10(5), 3705-3708 (2010)
A novel headspace solid-phase microextraction method using in situ derivatization and a diethoxydiphenylsilane fibre for the gas chromatography?mass spectrometry determination of urinary hydroxy polycyclic aromatic hydrocarbons.
Mattarozzi M, et al.
Journal of Chromatography A, 1216(30), 5634-5639 (2009)
Planar solid-phase microextraction-ion mobility spectrometry: a diethoxydiphenylsilane-based coating for the detection of explosives and explosive taggants.
Mattarozzi M, et al.
Analytical and Bioanalytical Chemistry, 399(8), 2741-2746 (2011)
F Bianchi et al.
Journal of chromatography. A, 1196-1197, 41-45 (2008-05-06)
An innovative solid-phase microextraction coating based on the use of diethoxydiphenylsilane synthesized by sol-gel technology was used for the determination of polycyclic aromatic hydrocarbons at trace levels in milk. The effects of time and temperature of extraction and acetone addition

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.