추천 제품
product name
o-Cresolphthalein, indicator grade
Grade
indicator grade
Quality Level
형태
powder
기술
titration: suitable
색상
beige
pH
8.2-9.8, colorless to red
mp
219-221 °C (lit.)
λmax
381 nm (2nd)
566 nm
ε (흡광계수)
≥10000 at 294-300 nm
≥39000 at 564-570 nm
≥5000 at 378-384 nm
응용 분야
diagnostic assay manufacturing
hematology
histology
저장 온도
room temp
SMILES string
Cc1cc(ccc1O)C2(OC(=O)c3ccccc23)c4ccc(O)c(C)c4
InChI
1S/C22H18O4/c1-13-11-15(7-9-19(13)23)22(16-8-10-20(24)14(2)12-16)18-6-4-3-5-17(18)21(25)26-22/h3-12,23-24H,1-2H3
InChI key
CPBJMKMKNCRKQB-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
O-Cresolphthalein has been used as a component in calcifying media for calcification assay.
생화학적/생리학적 작용
o-Cresolphthalein is a reversible pH indicator. The kinetics of the reverse pathway (red-purple to colorless) is slow, thereby making it an appropriate molecule to check flow patterns in ducts with corrugated walls. It is also used for the colorimetric determination of calcium content via the o-cresolphthalein complexone method. Binding of calcium to o-cresolphthalein, in the presence of alkaline conditions (pH 10-12), results in the formation of a red complex with an absorbance at 570-575nm.
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
Eyeshields, Gloves, type N95 (US)
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Clinical chemistry, 50(4), 741-746 (2004-02-14)
Gadolinium formulations, which are administered as contrast agents in magnetic resonance imaging examinations, interfere with colorimetric serum calcium determinations. We performed an in vitro study to determine the extent to which three gadolinium formulations-gadodiamide (Omniscan), gadopentetate dimeglumine (Magnevist), and gadoversetamide
European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies, 35(4), 297-300 (1997-04-01)
We evaluated bias and inaccuracy of four frequently used routine test systems for serum total calcium, using a candidate reference method based on ion chromatography. The mean biases and 95% confidence intervals that we observed were 0.0 +/- 0.59% for
Diabetic vascular calcification mediated by the collagen receptor discoidin domain receptor 1 via the Phosphoinositide 3-Kinase/Akt/Runt-related transcription factor 2 signaling axis
Arteriosclerosis, Thrombosis, and Vascular Biology, 38(8), 1878-1889 (2018)
Handbook on Metals in Clinical and Analytical Chemistry (1994)
European journal of epidemiology (2018-05-17)
Hyperphosphatemia has been associated with increased mortality in chronic kidney disease but the nature of such a relation in the general population is unclear. To investigate the association between phosphate (P) levels and all-cause and cause-specific mortality, we assessed two
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.