추천 제품
product name
N-Acetyl-L-glutamic acid, ReagentPlus®, 99%
Quality Level
제품 라인
ReagentPlus®
분석
99%
형태
powder
광학 활성
[α]22/D −15.6°, c = 1 in H2O
반응 적합성
reaction type: solution phase peptide synthesis
mp
194-196 °C (lit.)
응용 분야
peptide synthesis
저장 온도
2-8°C
SMILES string
CC(=O)N[C@@H](CCC(O)=O)C(O)=O
InChI
1S/C7H11NO5/c1-4(9)8-5(7(12)13)2-3-6(10)11/h5H,2-3H2,1H3,(H,8,9)(H,10,11)(H,12,13)/t5-/m0/s1
InChI key
RFMMMVDNIPUKGG-YFKPBYRVSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
법적 정보
ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany
Storage Class Code
11 - Combustible Solids
WGK
WGK 2
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
이미 열람한 고객
Biochemical medicine and metabolic biology, 47(1), 38-46 (1992-02-01)
N-Acetyl-L-glutamate synthetase (NAG synthetase) is a mitochondrial matrix enzyme which catalyzes the synthesis of N-acetyl-Lglutamate (NAG), a physiologic activator of the urea cycle enzyme carbamylphosphate synthetase I. Deficiency of NAG synthetase in humans has been reported only three times previously.
Clinical and investigative medicine. Medecine clinique et experimentale, 13(4), 183-188 (1990-08-01)
Liver tissue from 3 patients with carbamyl phosphate synthetase I deficiency and 11 patients with ornithine transcarbamylase deficiency was analyzed by Western blots for the presence of carbamyl phosphate synthetase I and ornithine transcarbamylase cross-reactive material with anti-rat enzyme antibodies.
Pediatric research, 27(4 Pt 1), 408-412 (1990-04-01)
N-acetylglutamate (NAG) content was measured in homogenates of liver and small intestine obtained from normal and 24-h starved syngeneic mice. Subsequently, NAG was determined in normal, and in carbamyl phosphate synthetase I and ornithine transcarbamylase enzyme-deficient human liver tissue homogenates.
Journal of chromatography. B, Biomedical applications, 657(1), 15-21 (1994-07-01)
Liquid chromatography-atmospheric pressure chemical-ionization mass spectrometry (LC-APCI-MS) was used for the analysis of N-acetylamino acids that could not be determined with an amino acid analyzer. LC-APCI-MS could directly detect the protonated molecular ions of various synthetic N-acetylamino acids, distinguishing N-acetylserine
Urological research, 10(2), 81-84 (1982-01-01)
A sensitive and reliable radioimmunoassay (RIA) for urinary unconjugated 5 alpha-androstane-3 alpha, 17 beta-diol is described. The mean overall recovery of unconjugated 5 alpha-androstane-3 alpha, 17 beta-diol was found to be 57.4%. The sensitivity of the assay was 79 fmol