추천 제품
양식
powder
Quality Level
입자 크기
200 μm
전이 온도
Tm 340-345 °C
SMILES string
F\C(F)=C(\F)F
InChI key
BFKJFAAPBSQJPD-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
- Ultrasonic activation of inert poly (tetrafluoroethylene): Demonstrates the activation of inert PTFE particles into piezoelectric electrets using ultrasound, which enables the piezocatalytic generation of reactive oxygen species, a significant advance in material science (Wang et al., 2021).
- Membrane preparation techniques with polytetrafluoroethylene: Discusses production techniques of porous polymeric membranes including PTFE, highlighting its application in separation technology, a critical area in industrial processes (Tan & Rodrigue, 2019).
- Enhancing expanded poly (tetrafluoroethylene) for biomaterials applications: Reviews the use of expanded PTFE (ePTFE) in biomaterials, focusing on its chemical properties and applications in medical devices and implants, contributing significantly to healthcare advancements (Cassady et al., 2014).
- Electret polyvinylidene fluoride nanofibers hybridized by polytetrafluoroethylene nanoparticles: This study explores the enhancement of air filtration performance through hybridizing electret polyvinylidene fluoride nanofibers with PTFE nanoparticles, presenting a novel approach to improving filtration efficiency (Wang et al., 2016).
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
이미 열람한 고객
René R E Steendam et al.
Nature communications, 5, 5543-5543 (2014-11-22)
The synthesis of enantiopure molecules from achiral precursors without the need for pre-existing chirality is a major challenge associated with the origin of life. We here show that an enantiopure product can be obtained from achiral starting materials in a
Ming Yang et al.
The Journal of thoracic and cardiovascular surgery, 150(1), 152-157 (2015-03-15)
Robotically assisted cardiac surgery is an alternative to conventional, open-chest surgery. Although studies have been done on the clinical effect, morbidity, and mortality of robotically assisted atrial myxoma excision, few have addressed surgical outcomes, such as pain, quality of life
Tobias Fink et al.
Anesthesiology, 122(1), 117-126 (2014-08-30)
Multicapillary column ion-mobility spectrometry (MCC-IMS) may identify volatile components in exhaled gas. The authors therefore used MCC-IMS to evaluate exhaled gas in a rat model of sepsis, inflammation, and hemorrhagic shock. Male Sprague-Dawley rats were anesthetized and ventilated via tracheostomy
Jianli Zou et al.
Nature communications, 5, 5254-5254 (2014-10-17)
Despite recent progress in preparing numerous types of nanosheets, it remains a difficult challenge to assemble the tiny building blocks into functional macroscale architectures suitable for practical applications. Here we introduce a diffusion driven layer-by-layer assembly process and demonstrate its
Johannes Lammer et al.
Journal of the American College of Cardiology, 62(15), 1320-1327 (2013-07-09)
The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long
Global Trade Item Number
SKU | GTIN |
---|---|
737992-5G | 4061832883700 |
737992-100G | 4061832883694 |
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..