콘텐츠로 건너뛰기
Merck
모든 사진(3)

Key Documents

182478

Sigma-Aldrich

Poly(tetrafluoroethylene)

powder, >40 μm particle size

동의어(들):

Fluorinated polymer, Fluoropolymer, PTFE

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
(CF2CF2)n
CAS Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

형태

powder

Quality Level

입자 크기

>40 μm

전이 온도

Tg 130 °C
Tm 327 °C

density

2 g/mL at 25 °C

SMILES string

F\C(F)=C(\F)F

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Poly(tetrafluoroethylene) (PTFE) is a stable fluoropolymer used in the field of coatings, thermal ceilings, supercapacitors, lubricators, bearings, and clinical applications.

애플리케이션

Poly(tetrafluoroethylene) can be used as a precursorto fabricate supercapacitors.

특징 및 장점

  • Chemically and biologically inert
  • Recyclable
  • Able to resist enzymatic and microbiological attack
  • Extremely low coefficient of friction
  • Insulating and dielectric properties

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

René R E Steendam et al.
Nature communications, 5, 5543-5543 (2014-11-22)
The synthesis of enantiopure molecules from achiral precursors without the need for pre-existing chirality is a major challenge associated with the origin of life. We here show that an enantiopure product can be obtained from achiral starting materials in a
Ming Yang et al.
The Journal of thoracic and cardiovascular surgery, 150(1), 152-157 (2015-03-15)
Robotically assisted cardiac surgery is an alternative to conventional, open-chest surgery. Although studies have been done on the clinical effect, morbidity, and mortality of robotically assisted atrial myxoma excision, few have addressed surgical outcomes, such as pain, quality of life
Tobias Fink et al.
Anesthesiology, 122(1), 117-126 (2014-08-30)
Multicapillary column ion-mobility spectrometry (MCC-IMS) may identify volatile components in exhaled gas. The authors therefore used MCC-IMS to evaluate exhaled gas in a rat model of sepsis, inflammation, and hemorrhagic shock. Male Sprague-Dawley rats were anesthetized and ventilated via tracheostomy
Jianli Zou et al.
Nature communications, 5, 5254-5254 (2014-10-17)
Despite recent progress in preparing numerous types of nanosheets, it remains a difficult challenge to assemble the tiny building blocks into functional macroscale architectures suitable for practical applications. Here we introduce a diffusion driven layer-by-layer assembly process and demonstrate its
Johannes Lammer et al.
Journal of the American College of Cardiology, 62(15), 1320-1327 (2013-07-09)
The hypothesis that endovascular treatment with covered stents has equal risks but higher efficacy than bare-metal stents (BMS) in long femoropopliteal artery disease was tested. Although endovascular treatment of short superficial femoral artery lesions revealed excellent results, efficacy in long

문서

Materials Issues in Polymer Electrolyte Membrane Fuel Cells

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.