추천 제품
형태
granular
용융 지수
6 g/10 min (380°C/2.16 kg)
ISO 1628
50 mL/g, in phenol/1,2-dichlorobenzene(lit.)
전이 온도
Tg (DSC) 221 °C (onset)
solubility
aniline, dimethylacetamide and pyridine: soluble
density
1.37 g/mL at 25 °C (lit.)
SMILES string
Oc1ccc(cc1)S(=O)(=O)c2ccc(O)cc2
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Used in electrical connectors, printed circuit boards, sterilizable equipment and appliance covers.
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Acute Tox. 4 Oral
Storage Class Code
11 - Combustible Solids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
Therapeutics and clinical risk management, 14, 1-9 (2018-01-04)
The success and the quality of hemodialysis therapy are mainly related to both clearance and biocompatibility properties of the artificial membrane packed in the hemodialyzer. Performance of a membrane is strongly influenced by its interaction with the plasma protein repertoire
Internal filtration, filtration fraction, and blood flow resistance in high- and low-flux dialyzers.
Clinical hemorheology and microcirculation, 58(3), 455-469 (2013-11-21)
It was the aim to examine the fluid flow in blood and dialysate compartments of highly permeable hollow fiber dialyzers where internal filtration contributes to solute removal but where excessive filtration bears a risk of cell activation and damage. Flow
Langmuir : the ACS journal of surfaces and colloids, 28(37), 13284-13293 (2012-08-17)
In the present study, photoresponsive surface molecularly imprinted poly(ether sulfone) microfibers are prepared via nitration reaction, the wet-spinning technique, surface nitro reduction reaction, and surface diazotation reaction for the selectively photoregulated uptake and release of 4-hydrobenzoic acid. The prepared molecularly
Analytica chimica acta, 740, 50-57 (2012-07-31)
A method for the determination of seven perfluorinated carboxylic acids and perfluorooctane sulphonate (PFOS) in aqueous samples using low-cost polymeric sorptive extraction as sample preparation technique, followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination has been developed and validated. Simplicity
Journal of colloid and interface science, 386(1), 428-440 (2012-08-23)
Sulfonated polyethersulfone (SPES) and poly (acrylonitrile-co-acrylic acid-co-vinyl pyrrolidone) (P(AN-AA-VP)), which provided sulfonic acid (-SO(3)H) and carboxylic acid groups (-COOH), respectively, were used to modify polyethersulfone (PES) membrane with a heparin-like surface by blending method. The SPES was prepared by sulfonation
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.