32250
Diethylene glycol monobutyl ether
≥98.0% (GC)
동의어(들):
DEGBE, 2-(2-Butoxyethoxy)ethanol, BDG, Butyldiglycol
로그인조직 및 계약 가격 보기
모든 사진(1)
About This Item
Linear Formula:
CH3(CH2)3OCH2CH2OCH2CH2OH
CAS Number:
Molecular Weight:
162.23
Beilstein:
1739225
EC Number:
MDL number:
UNSPSC 코드:
12352100
PubChem Substance ID:
NACRES:
NA.22
bp:
224-228 °C (lit.)
추천 제품
분석
≥98.0% (GC)
양식
liquid
기술
GC/GC: suitable
불순물
≤0.05% water
refractive index
n20/D 1.432
pH
7
bp
224-228 °C (lit.)
density
0.953 g/mL at 20 °C (lit.)
SMILES string
CCCCOCCOCCO
InChI
1S/C8H18O3/c1-2-3-5-10-7-8-11-6-4-9/h9H,2-8H2,1H3
InChI key
OAYXUHPQHDHDDZ-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Diethylene glycol monobutyl ether (DEGBE) is used:
- In the preparation of blocked isocyanate systems for coil coating, electro-coating and powder coating.
- As a cosurfactant in the formation of microemulsions.
- As a structural component of various liquid crystals.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2
Storage Class Code
10 - Combustible liquids
WGK
WGK 1
Flash Point (°F)
210.2 °F - closed cup
Flash Point (°C)
99 °C - closed cup
개인 보호 장비
Eyeshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
Doping molecular semiconductors: n-type doping of a liquid crystal perylene diimide.
Gregg BA and Cormier RA
Journal of the American Chemical Society, 123(32), 7959-7960 (2001)
Synthesis and characterization of diethylene glycol monobutyl ether?Blocked diisocyanate crosslinkers.
Ranjbar Z, et al.
Progress in Organic Coatings, 69(4), 426-431 (2010)
Microemulsion systems with monobutyl ether of ethylene glycol or diethylene glycol as cosurfactant.
Chew CH, et al.
Journal of Dispersion Science and Technology, 9(1), 17-31 (1988)
Christopher R Gibson et al.
Journal of the American Society for Mass Spectrometry, 14(11), 1247-1249 (2003-11-05)
Tandem liquid chromatography-mass spectrometry coupled to online radioactive material detection (LC/RAM/MS/MS) is a technique that is used routinely for in vivo and in vitro drug metabolism studies and allows for a simultaneous correlation between radiochemical peaks and mass spectral data.
W Mücke et al.
Zentralblatt fur Hygiene und Umweltmedizin = International journal of hygiene and environmental medicine, 201(4-5), 377-386 (1999-01-23)
The investigation of building products in test chambers contains so far only analytical and sensory measurements. In this paper, first experiments for the direct testing of the acute toxicity of building product emissions with the bioluminescence inhibition test are presented.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.