추천 제품
Quality Level
분석
99%
형태
liquid
refractive index
n20/D 1.416 (lit.)
bp
120-122 °C/10 mmHg (lit.)
density
1.012 g/mL at 25 °C (lit.)
SMILES string
CCCOP(=O)(OCCC)OCCC
InChI
1S/C9H21O4P/c1-4-7-11-14(10,12-8-5-2)13-9-6-3/h4-9H2,1-3H3
InChI key
RXPQRKFMDQNODS-UHFFFAOYSA-N
일반 설명
Tripropyl phosphate is an organophosphorus flame retardant and plasticizer.
애플리케이션
Tripropyl phosphate has been used as external standard in sampling of organophosphate triesters in indoor air by using solid phase extraction cartridges.
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Acute Tox. 4 Oral
Storage Class Code
10 - Combustible liquids
WGK
WGK 3
Flash Point (°F)
235.4 °F - closed cup
Flash Point (°C)
113 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
Journal of environmental monitoring : JEM, 7(4), 344-348 (2005-03-31)
In this paper we demonstrate the use of SPE cartridges for sampling of organophosphate triesters in indoor air by adsorptive enrichment. The method has been optimised for the sampling and analysis of organophosphate triesters using a 25 mg aminopropyl silica
Environmental science & technology, 42(6), 1898-1903 (2008-04-16)
The concentration levels, distribution, and seasonal fluctuations of 12 organophosphorus flame retardants and plasticizers (OPs), of which some are reported to be toxic to aquatic organisms, were investigated in lakes from June 2006 to June 2007. Three volcanic lakes located
Environment international, 130, 104914-104914 (2019-06-22)
As potential substitutes for polybrominated diphenyl ethers (PBDEs), organophosphate flame retardants (OPFRs) have been frequently detected in the environment. However, the genotoxicity induced by these OPFRs has rarely been described, and the results reported in previous studies are conflicting and
Environmental research, 167, 437-444 (2018-08-21)
Organophosphate esters (OPEs) are novel ubiquitous contaminants that are attracting growing concern, but their emissions into the environment are still poorly understood. In this study, 12 OPEs were measured in fine particulate matter (PM2.5) at 20 industrial sites in an
Chemosphere, 184, 185-191 (2017-06-09)
Indoor dust has been widely used to monitor flame retardants (FRs) in indoor environment, but most studies only focused on floor dust. In the present study, FRs were examined in indoor dust from different locations. Dust from air conditioner (AC)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.