추천 제품
Quality Level
분석
97%
refractive index
n20/D 1.4055 (lit.)
bp
89-91 °C (lit.)
density
0.748 g/mL at 25 °C (lit.)
SMILES string
CCC(N)CC
InChI
1S/C5H13N/c1-3-5(6)4-2/h5H,3-4,6H2,1-2H3
InChI key
PQPFFKCJENSZKL-UHFFFAOYSA-N
애플리케이션
1-Ethylpropylamine has been used:
- in the synthesis of (1-ethyl-propyl)-[3-(4-methoxy-2-methylphenyl)-2-methyl-6,7-dihydro-5H-1,4,8a-triaza-s-indacen-8-yl]-amine
- in the synthesis of monoclinic VPO4·H2O
- as internal standard in the screening of aziridine and 2-chloroethylamine in active pharmaceutical ingredients by gas chromatography-mass spectrometry.
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Flam. Liq. 2 - Skin Corr. 1B
Storage Class Code
3 - Flammable liquids
WGK
WGK 3
Flash Point (°F)
35.6 °F - closed cup
Flash Point (°C)
2 °C - closed cup
개인 보호 장비
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Bioorganic & medicinal chemistry, 19(18), 5432-5445 (2011-08-26)
To identify an orally active corticotropin-releasing factor 1 receptor antagonist, a series of 6,7-dihydro-5H-cyclopenta[d]pyrazolo[1,5-a]pyrimidines and their derivatives were designed, synthesized and evaluated. An in vitro study followed by in vivo and pharmacokinetic studies of these heterotricyclic compounds led us to
Journal of pharmaceutical and biomedical analysis, 55(3), 458-465 (2011-03-23)
A simple, fast and fully automated method for the screening of aziridine (AZD) and 2-chloroethylamine (CEA) in active pharmaceutical ingredients (API) has been developed. The method is based on the in-fiber derivatization of the amines extracted from the sample headspace
Reaction of vanadium phosphates with alcohols at elevated temperature and pressure.
Journal of Materials Chemistry, 15(31), 3214-3220 (2005)
Journal of separation science, 42(22), 3470-3478 (2019-09-14)
On-spot derivatization has been suggested for the modification of primary amine containing compounds for their analysis by thin-layer chromatography hyphenated with matrix-assisted laser desorption ionization mass spectrometry. The proposed approach was based on post-chromatographic treatment of separated analytes inside the
Lab on a chip, 19(20), 3490-3498 (2019-09-19)
While LC-MS-based proteomics with high nanograms to micrograms of total protein has become routine, the analysis of samples derived from low cell numbers is challenged by factors such as sample losses, or difficulties encountered with the manual manipulation of small
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.