Serial intravascular ultrasound observations from the Tryton first-in-man study.

EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology (2014-08-21)
Akiko Maehara, Robert Jan van Geuns, Yves Louvard, Ralf Müller, Eberhard Grube, Marie-Claude Morice, H Richard Davis, Aaron V Kaplan, Yoshinobu Onuma, Patrick W Serruys, Gary S Mintz
要旨

To report serial intravascular ultrasound (IVUS) findings of bifurcation lesions treated with the dedicated Tryton Side Branch Stent to assess mechanisms of restenosis. The Tryton FIM study was a multicentre, prospective, single-arm, "first-in-man" study to treat de novo bifurcation lesions. Minimum lumen area (MLA) sites and overall volumes were analysed within main vessels and side branches. Overall, 27 main vessels and 22 side branches had paired baseline and follow-up IVUS. The post-intervention main vessel MLA decreased from 5.3 (4.1, 6.2) to 4.8 (3.4, 5.7) mm2 at follow-up, p=0.02, and the side branch MLA decreased from 3.5 (3.0, 3.8) to 2.5 (2.2, 3.2) mm2, p=0.0005. Stent area at the side branch did not change (mean stent area from 4.0 [3.3, 4.1] to 3.8 [3.4, 4.2] mm3/mm, p=0.95). Neointimal hyperplasia (NIH) net volume obstruction (%) measured 1.8% (0.5, 7.0) for the entire main vessel and 14.9% (2.3, 31.1) for the entire side branch stents. In both main vessel and side branches the decrease in lumen area correlated significantly with NIH. Serial IVUS analysis of a new side branch Tryton stent showed no chronic stent recoil. Side branch underexpansion was common and along with superimposed NIH contributed to the reduction in lumen dimensions at follow-up.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
クロム, powder, ≥99% trace metals basis, <45 μm
Sigma-Aldrich
クロム, powder, 99.5%, −100 mesh
Sigma-Aldrich
クロム, chips, 99.995% trace metals basis
Sigma-Aldrich
クロム, chips, thickness ~2 mm, 99.5%
クロム, foil, light tested, 25x25mm, thickness 0.025mm, permanent polyester support, 99.99+%
クロム, rod, 25mm, diameter 2.0mm, 99.7+%
クロム, rod, 10mm, diameter 2.0mm, 99.7+%
クロム, microfoil, disks, 10mm, thinness 1.0μm, specific density 719μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, microfoil, disks, 25mm, thinness 1.0μm, specific density 719μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, bar, 100mm x 2mm x 2mm, 99.7+%
クロム, rod, 10mm, diameter 5.0mm, 99.7+%
クロム, microfoil, disks, 10mm, thinness 0.05μm, specific density 37.27μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, rod, 100mm, diameter 5.0mm, 99.7+%
クロム, microfoil, disks, 10mm, thinness 0.25μm, specific density 178.7μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, microfoil, disks, 25mm, thinness 0.25μm, specific density 178.7μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, foil, 50x50mm, thickness 3.0mm, hard, 99.95%
クロム, foil, not light tested, 25x25mm, thickness 0.0125mm, permanent polyester support, 99.99+%
クロム, foil, not light tested, 25x25mm, thickness 0.015mm, permanent polyester support, 99.99+%
クロム, foil, not light tested, 25x25mm, thickness 0.01mm, permanent polyester support, 99.99+%
クロム, foil, not light tested, 25x25mm, thickness 0.03mm, permanent polyester support, 99.99+%
クロム, microfoil, disks, 10mm, thinness 0.025μm, specific density 18.21μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, foil, light tested, 25x25mm, thickness 0.05mm, permanent polyester support, 99.99+%
クロム, foil, not light tested, 50x50mm, thickness 0.03mm, permanent polyester support, 99.99+%
クロム, microfoil, disks, 10mm, thinness 0.5μm, specific density 355μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, microfoil, disks, 25mm, thinness 0.05μm, specific density 37.27μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, microfoil, disks, 25mm, thinness 0.5μm, specific density 355μg/cm2, permanent mylar 3.5μm support, 99.99+%
クロム, rod, 50mm, diameter 2.0mm, 99.7+%
クロム, rod, 50mm, diameter 5.0mm, 99.7+%
クロム, foil, 25x25mm, thickness 2.0mm, hard, 99.7+%
クロム, foil, not light tested, 100x100mm, thickness 0.025mm, permanent polyester support, 99.99+%