コンテンツへスキップ
Merck
  • Evaluation of the Anderson Baird-Parker direct plating method for enumerating Escherichia coli in water.

Evaluation of the Anderson Baird-Parker direct plating method for enumerating Escherichia coli in water.

The Journal of applied bacteriology (1988-01-01)
A H Havelaar, M During
要旨

The direct plating (DP) method for enumerating Escherichia coli in food was adapted for water analysis by membrane filtration and a standardized protocol was described. The DP method was found to give equal or better recoveries of E. coli than a membrane filtration method using 0.1% sodium lauryl sulphate agar; the repeatability of the DP method was markedly better. The necessity to transfer membranes from the non-selective medium tryptone soy agar (TSA) to the selective medium tryptone bile agar (TBA) after pre-incubation for 4 h was considered disadvantageous for practical purposes. A double-layer method, where the membrane filter is placed on a layer of TSA poured over TBA, with incubation in an incubator that automatically switches from 37 degrees to 44 degrees C after 4 h, was found to be an acceptable alternative. Recovery of E. coli and inhibition of competitive flora were equal or only slightly less than for the standard DP method.

材料
製品番号
ブランド
製品内容

Millipore
トリプトン水, suitable for microbiology, NutriSelect® Plus