Passa al contenuto
Merck
  • Inlet backflushing device for the improvement of comprehensive two dimensional gas chromatographic separations.

Inlet backflushing device for the improvement of comprehensive two dimensional gas chromatographic separations.

Journal of chromatography. A (2015-06-02)
Matthew Edwards, Tadeusz Górecki
ABSTRACT

Comprehensive two-dimensional gas chromatography (GC×GC) is recognised as a powerful tool for the separation of complex mixtures of volatile and semi-volatile compounds. In the analysis of challenging samples containing highly concentrated, active analytes or those with complicated matrices, it is often the case that less than ideal chromatography is produced. GC×GC chromatograms of such samples typically contain broad, tailing analyte bands. This results in difficulties with quantitation and poor utilisation of the separation space. In this study we investigated the inlet and the modulator as the potential sources of these tailing bands. A simple inlet backflushing device was developed to isolate the inlet from the primary column after the injection, and a similar setup was used to isolate the modulator from the primary column. The device allowed us to divert carrier gas flow back through the inlet at a specified time after the injection, while allowing analytes to pass through the column for separation. Analytes retained within the inlet were prevented from entering the column, and were subsequently removed via the carrier gas split line. The study revealed that the inlet plays a significant role in the development of tailing chromatographic bands, while the modulator simply modulates the already elongated band. Inlet backflushing is a cheap, simple and effective tool that can be used to improve the chromatography of problematic GC×GC analyses of samples consisting of concentrated and active analytes, those derived from natural products and containing complicated matrices.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Sodio cloruro, for molecular biology, DNase, RNase, and protease, none detected, ≥99% (titration)
Sigma-Aldrich
Sodio citrato tribasico, ACS reagent, ≥99.0%
Sigma-Aldrich
Sodio cloruro, 5 M in H2O, BioReagent, for molecular biology, suitable for cell culture
Sigma-Aldrich
Sodio cloruro, 0.9% in water, BioXtra, suitable for cell culture
Sigma-Aldrich
Sodio cloruro, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%
Sigma-Aldrich
Sodio citrato tribasico, ≥99%, FG
Sigma-Aldrich
Sodio cloruro, BioXtra, ≥99.5% (AT)
SAFC
Sodio cloruro, 5 M
Sigma-Aldrich
Solfato di magnesio, BioReagent, suitable for cell culture, suitable for insect cell culture
Sigma-Aldrich
Sodio citrato tribasico, for molecular biology, ≥99%
Sigma-Aldrich
Sodio cloruro, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
Sodio cloruro, BioUltra, for molecular biology, ≥99.5% (AT)
Sigma-Aldrich
Sodio cloruro, 99.999% trace metals basis
Sigma-Aldrich
Sodio cloruro, 5 M
Sigma-Aldrich
Magnesium sulfate solution, for molecular biology, 1.00 M±0.04 M
Sigma-Aldrich
Sodio citrato tribasico, meets USP testing specifications
Sigma-Aldrich
Sodio citrato tribasico, BioUltra, for molecular biology
Sigma-Aldrich
Sodio cloruro, meets analytical specification of Ph. Eur., BP, USP, 99.0-100.5%
Sigma-Aldrich
Sodium hydrogencitrate sesquihydrate, ReagentPlus®, 99%
Sigma-Aldrich
Magnesium sulfate solution, BioUltra, for molecular biology
Sigma-Aldrich
Sodio citrato tribasico, puriss. p.a., ACS reagent, ≥99.0% (NT)
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Solfato di magnesio, ≥99.99% trace metals basis
Sigma-Aldrich
Sodio cloruro, BioPerformance Certified, ≥99% (titration), suitable for insect cell culture, suitable for plant cell culture