Passa al contenuto
Merck
  • Simultaneous determination of sixteen amide fungicides in vegetables and fruits by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry.

Simultaneous determination of sixteen amide fungicides in vegetables and fruits by dispersive solid phase extraction and liquid chromatography-tandem mass spectrometry.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2015-03-24)
Yin-Liang Wu, Ruo-Xia Chen, Yong Zhu, Jian Zhao, Ting Yang
ABSTRACT

A modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) method using multi-walled carbon nanotubes (MWCNTs) as a reversed-dispersive solid phase extraction (r-dSPE) material combined with ultra-high liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) was developed for the simultaneous determination of 16 novel amide fungicides in vegetables and fruits. After extraction with acetonitrile, a dSPE cleanup procedure, which was developed after the optimization of the type and amount of MWCNTs, the pH value of the extract, the extraction time for MWCNTs, and the type of eluent with MWCNTs material, was conducted. The determination of the target compounds was conducted in less than 7.0 min while the specificity is ensured through the MRM acquisition mode. The linearity of the analytical response across the studied range of concentrations (0.25-500 μg/L) was excellent, obtaining correlation coefficients higher than 0.997. The samples were quantified with the matrix matched standard solutions. The average recoveries in cabbage, celery, strawberry, and grape at three spiked levels (0.01, 0.5, and 5.0mg/kg) were ranged from 72.4 to 98.5% with all RSDs lower than 10%. The limits of detection were below 0.003 mg/kg and the limits of quantification did not exceed 0.01 mg/kg in all matrices. The method demonstrated to be suitable for the simultaneous determination of 16 novel amide fungicides in vegetables and fruits.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Sodio idrossido, ACS reagent, ≥97.0%, pellets
Sigma-Aldrich
Sodio idrossido, reagent grade, ≥98%, pellets (anhydrous)
Sigma-Aldrich
Acido formico, reagent grade, ≥95%
Sigma-Aldrich
Idrossido di sodio, 50% in H2O
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Acido formico, ACS reagent, ≥96%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Cicloesano, ACS reagent, ≥99%
Sigma-Aldrich
Idrossido di sodio, BioUltra, for molecular biology, 10 M in H2O
Sigma-Aldrich
Cicloesano, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Idrossido di sodio, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%