Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

SCYT-91K-PXBK14

Millipore

Ovine Cytokine/Chemokine Panel 1 14 Plex

Immuno-Oncology Multiplex Assay

Sinonimo/i:

14 Plex Chemokine Panel, Ovine Cytokine Assay, Ovine Cytokine Panel

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
12161503
NACRES:
NA.47

Reattività contro le specie

mouse

Confezionamento

pkg of 1 ea

Produttore/marchio commerciale

Milliplex®

assay range

accuracy: 101
(Galectin-1)

accuracy: 102
(PD-L2)

accuracy: 103
(CD80/B7-1)

accuracy: 103
(IFNγ)

accuracy: 104
(CTLA-4/CD152)

accuracy: 104
(TLR-2)

accuracy: 105
(4-1BBL/TNFSF9)

accuracy: 105
(BCA-1/CXCL-13)

accuracy: 105
(CD25/IL-2Rα)

accuracy: 105
(IL-10)

accuracy: 105
(LAG-3)

accuracy: 106
(5’-NT/CD73)

accuracy: 106
(PD-1)

accuracy: 106
(TIM-3)

accuracy: 106
(TNFα)

accuracy: 107
(CD137/4-1BB)

accuracy: 107
(CD27)

accuracy: 108
( Galectin-3)

accuracy: 108
(E-Cadherin)

accuracy: 108
(HVEM)

accuracy: 109
(CD40)

accuracy: 109
(GITR)

accuracy: 110
(B7-H2/ICOSL)

accuracy: 110
(CD226/DNAM-1)

accuracy: 111
(BTLA)

accuracy: 94
(GranzymeB)

accuracy: 95
(B7-H3/CD276)

accuracy: 96
(PD-L1)

sensitivity: 14 - 10000  pg/mL
(4-1BBL/TNFSF9)

standard curve range: 1.4 - 1000 pg/mL
(HVEM)

standard curve range: 1.4 - 1000 pg/mL
(IFNγ)

standard curve range: 11 - 8000  pg/mL
(IL-10)

standard curve range: 137 - 100000 pg/mL
(5’-NT/CD73)

standard curve range: 14 - 10000 pg/mL
(CD226/DNAM-1)

standard curve range: 14 - 10000 pg/mL
(CD40)

standard curve range: 14 - 10000 pg/mL
(PD-L1)

standard curve range: 2.7 - 2000  pg/mL
(CD25/IL-2Rα)

standard curve range: 21 - 15000 pg/mL
(BTLA)

standard curve range: 27 - 20000 pg/mL
(B7-H2/ICOSL)

standard curve range: 27 - 20000 pg/mL
(BCA-1/CXCL-13)

standard curve range: 3.4 - 2500  ng/mL
(Galectin-1)

standard curve range: 3.4 - 2500 ng/mL
(B7-H3/CD276)

standard curve range: 34.3 - 25000 pg/mL
(CD80/B7-1)

standard curve range: 342 - 250000 pg/mL
(E-Cadherin)

standard curve range: 4.1 - 3000  pg/mL
(TNFα)

standard curve range: 41 - 30000  pg/mL
(GITR)

standard curve range: 41 - 30000  pg/mL
(GranzymeB)

standard curve range: 41 - 30000 pg/mL
(Galectin-3)

standard curve range: 412 - 300000  pg/mL
(LAG-3)

standard curve range: 412 - 300000 pg/mL
(TLR-2)

standard curve range: 5.5 - 4000  pg/mL
(CD137/4-1BB )

standard curve range: 5.5 - 4000  pg/mL
(CTLA-4/CD152)

standard curve range: 5.5 - 4000  pg/mL
(TIM-3)

standard curve range: 55 - 40000 pg/mL
(CD27)

standard curve range: 55 - 40000 pg/mL
(PD-1)

standard curve range: 6.9 - 5000  pg/mL
(PD-L2)

inter-assay cv: <20%
intra-assay cv: <10%

tecniche

multiplexing: suitable

Compatibilità

configured for Premixed

Metodo di rivelazione

fluorometric (Luminex® xMAP®)

Condizioni di spedizione

wet ice

Temperatura di conservazione

2-8°C

Descrizione generale

Immune checkpoint proteins are key regulators of the immune system and drug targets of cancer immunotherapy. Immune checkpoint molecules have been found on the cell surface of immune cells and tumor cells as activating receptors or inhibitory receptors. Immune checkpoint inhibitors, such as blocking antibodies to cytotoxic T lymphocyte-associated antigen-4 (CTLA-4), programmed cell death protein-1 (PD-1) and programmed cell death ligand 1 (PD-L1), have demonstrated significant efficacy in the treatment of a variety of cancers. Recent studies have also shown many immune checkpoint proteins can undergo alternative splicing or proteolytic cleavage to produce soluble checkpoint proteins. The expression levels of soluble and cell-surface immune checkpoint proteins in the circulation and in tumor-microenvironment (TME) may be used as putative immune-based biomarkers for cancer research and biomarker discovery in immunological diseases.
MILLIPLEX® Mouse Immuno-Oncology Checkpoint Protein Panel 1 is a 28-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma, cell culture supernatant, cell lysate, and tissue/tumor extract samples: 4-1BBL/TNFSF9, 5′-NT/CD73, B7-H2/ICOSL, B7-H3/CD276, BCA-1/CXCL-13, BTLA, CD137/4-1BB, CD226/DNAM-1, CD25/IL-2Rα, CD27, CD40, CD80/B7-1, CTLA-4/CD152, E-cadherin, Galectin-1, Galectin-3, GITR, Granzyme B, HVEM, IFNγ, IL-10, LAG-3, PD-1, PD-L1, PD-L2, TIM-3, TLR-2, and TNFα.

Panel Type: MAGNETIC Circulating Cancer

Specificità

Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.

Applicazioni

The Mouse Immuno-Oncology Checkpoint Protein Panel 1 bead-based multiplex panel, using the Luminex® xMAP® technology, enables the simultaneous analysis of 28 immune checkpoint proteins in mouse serum, plasma, cell culture supernatant, cell lysate, and tissue/tumor extract samples.
This is an overnight incubation assay (16-18 hours at 2-8ºC).
A maximum of 25 μL per well 1:2 diluted serum or plasma can be used.
Tissue culture samples may be run neat or appropriately diluted in control medium.
Note: Best results using cell/tissue lysate samples may require diluting in assay buffer while testing similarly diluted lysis buffer for matrix effects.

Research Category: Cancer/Immuno-oncology

Analytes:
4-1BBL/TNFSF9
5’-NT/CD73
B7-H2/ICOSL
B7-H3/CD276
BCA-1/CXCL-13
BTLA
CD137/4-1BB
CD226/DNAM-1
CD25/IL-2Rα
CD27
CD40
CD80/B7-1
CTLA-4/CD152
E-cadherin
Galectin-1
Galectin-3
GITR
Granzyme B
HVEM
IFNγ
IL-10
LAG-3
PD-1
PD-L1
PD-L2
TIM-3
TLR-2
TNFα

Caratteristiche e vantaggi

Design your multiplex kit by choosing available analytes within this panel.

Confezionamento

96-well plate

Altre note

Sensitivity: Refer to kit protocol for sensitivities for individual cytokines/chemokines.

Note legali

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Esclusione di responsabilità

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Avvertenze

Danger

Classi di pericolo

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Organi bersaglio

Respiratory Tract

Codice della classe di stoccaggio

10 - Combustible liquids


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.