Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

EZBRAIN-SET

Millipore

Human Amyloid β40 and Amyloid β42 ELISA Kit

measures Amyloid β40 and Amyloid β42 in 50 μL tissue or cell lysate; combo pack

Sinonimo/i:

Amyloid β40/β42 ELISA, Brain ELISA Kit, Human Brain Amyloid ELISA

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
12161503
NACRES:
NA.84

product name

Human Amyloid β40 and Amyloid β42 Brain ELISA,

Reattività contro le specie

human

Livello qualitativo

Confezionamento

kit of 2 × 96 wells

Parametri

50 μL sample volume (Overnight assay)

assay range

sensitivity: 6.0 pg/mL
(The lowest level of Amyloid β1-40 standard used in this assay ; 50 μL sample size)

sensitivity: 8 pg/mL
(The lowest level of Amyloid ß1-42 standard used in this assay; 50 μL sample size)

inter-assay cv: <10
intra-assay cv: <10
standard curve range: 16-500 pg/mL

tecniche

ELISA: suitable

input

sample type tissue/cellular lysate

applicazioni

research use

Metodo di rivelazione

colorimetric (450nm/590nm)

Condizioni di spedizione

wet ice

Temperatura di conservazione

2-8°C

Informazioni sul gene

human ... APP(351)

Specificità

The Amyloid β40 ELISA uses monoclonal anti-Aβ antibodies with high selectivity for human Aβ. The capture antibody recognizes the C-terminal end of Amyloid β1-40, which causes a high selectivity for Aβ 40. The cross-reactivity of the used antibodies to other Amyloid peptides was tested by ELISA and BIACORE and shows no significant cross-reactivity to Aβ1-38, Aβ1-39, Aβ1-42, Aβ1-43 and Aβ1-44. The Amyloid β42 ELISA uses monoclonal anti-Aβ antibodies with high selectivity for human Aβ. The capture antibody recognizes the C-terminal end of Amyloid β1-42, which causes a high selectivity for Aβ42. The cross-reactivity of the used antibodies to other Amyloid peptides was tested by ELISA and BIACORE and shows no significant cross-reactivity to Aβ1-38, Aβ1-39, Aβ1-42, Aβ1-43 and Aβ1-44.


Used to detect/quantify: Amyloid β40 & Amyloid β42

Applicazioni

These assays require 50 µl of sample and are overnight assays.

Confezionamento

96-well plate

Stoccaggio e stabilità

Components in the kit can be stored up to 2 weeks at 2-8°C

Altre note

Contact technical support for information

Esclusione di responsabilità

For research use only. Not for use in diagnostic procedures.

Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.