1.15498
HPTLC plates, Silica gel 60 RP-18 F₂₅₄s with concentrating zone 20 x 2.5 cm
pkg of 25 plates, plate L × W 20 cm × 10 cm, glass support
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Materiali
glass support
silica gel 60 matrix
Livello qualitativo
Caratteristiche
binder Organic Polymer
fluorescent indicator
Confezionamento
pkg of 25 plates
tecniche
HPTLC: suitable
Spessore strato
150-200 μm
Lungh. × largh. lastra
20 cm × 10 cm
Dimensione particelle
5-6 μm
Dimensione pori
60 Å medium pore diameter
Temperatura di conservazione
2-30°C
Descrizione generale
25 Glass plates 20 x 10 cm
These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples. Our concentrating zone plates are based on different adsorption properties of two adsorbents. The first is a large pore concentrating adsorbent where the samples are applied; the second is a selective layer for separation. Regardless of the spots’ shape, size, or position, the sample always concentrates as a narrow band where the two adsorbents overlap and where the separation starts. These plates allow users to quickly and easily apply any kind of sample, even large volumes of diluted samples.
Linkage
Replaces: 15498-6; 15498
Risultati analitici
Specific surface area (according to BET; 5-Pt. measurement): 480 - 540 m²/g
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
layer thickness concentrating zone: 70 - 110 µm
Fluctuation in the thickness of the concentration zone: ≤ 35 µm
Chromatographic testings:
A) cholesterin test
hRf-values
- cholesterin, cholesterin test:
11 - 23
B) Steroide test
- methyltestosterone, steroid test: 20 - 40
- Reichstein S, steroid test: 50 - 70
- hydrocortisone, steroid test: 65 - 85
Typical value determined on a activated plate (120°C, 15 min)
Eluent a) acetone/ water (95/5 v/v)
Eluent b) acetonitrile/ water (70/30 v/v)
Pore volume (N₂-isotherm): 0.74 - 0.84 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
layer thickness concentrating zone: 70 - 110 µm
Fluctuation in the thickness of the concentration zone: ≤ 35 µm
Chromatographic testings:
A) cholesterin test
hRf-values
- cholesterin, cholesterin test:
11 - 23
B) Steroide test
- methyltestosterone, steroid test: 20 - 40
- Reichstein S, steroid test: 50 - 70
- hydrocortisone, steroid test: 65 - 85
Typical value determined on a activated plate (120°C, 15 min)
Eluent a) acetone/ water (95/5 v/v)
Eluent b) acetonitrile/ water (70/30 v/v)
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.