Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

487104

Supelco

Ethylbenzene solution

NMR reference standard, 0.1% in chloroform-d (99.8 atom % D), TMS 0.01 %, NMR tube size 5 mm × 8 in.

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula empirica (notazione di Hill):
C8H10
Numero CAS:
Peso molecolare:
106.17
Numero MDL:
Codice UNSPSC:
12142201
ID PubChem:
NACRES:
NA.24

Grado

NMR reference standard
analytical standard

Livello qualitativo

Composizione

TMS, 0.01%

Concentrazione

0.1% in chloroform-d (99.8 atom % D)

tecniche

NMR: suitable

Misura tubo NMR

5 mm × 8 in.

applicazioni

environmental

Formato

single component solution

Stringa SMILE

CCc1ccccc1

InChI

1S/C8H10/c1-2-8-6-4-3-5-7-8/h3-7H,2H2,1H3
YNQLUTRBYVCPMQ-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Applicazioni

Ethylbenzene solution may be used as NMR reference standard for 1H sensitivity test to assess the quality of the 1D NMR spectra and 2D NMR spectra in the external current mode.

Caratteristiche e vantaggi

1H sensitivity

Quantità

5 mm O.D. tube contains 0.700 mL.

Pittogrammi

Skull and crossbonesHealth hazard

Avvertenze

Danger

Classi di pericolo

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Carc. 2 - Eye Irrit. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Oral - STOT SE 3

Organi bersaglio

Central nervous system, Liver,Kidney

Codice della classe di stoccaggio

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable

Dispositivi di protezione individuale

Eyeshields, Faceshields, Gloves


Elenchi normativi

Forniamo informazioni su eventuali restrizioni prevalentemente per i prodotti chimici. Per altre tipologie di prodotto siamo in grado di fornire soltanto informazioni limitate. Nessuna segnalazione significa che nessuno dei componenti è citato in un elenco. È dovere dell’utilizzatore assicurarsi che il prodotto venga impiegato in maniera sicura e a norme di legge.

EU REACH Annex XVII (Restriction List)

CAS No.

Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 5

1 of 5

1,4-Dioxane solution NMR reference standard, 40% in benzene-d6 (99.6 atom % D), NMR tube size 5 mm × 8 in.

Supelco

736171

1,4-Dioxane solution

Ethylbenzene analytical standard

Supelco

03079

Ethylbenzene

Formamide solution NMR reference standard, 90% in DMSO-d6 (99.9 atom % D), NMR tube size 5 mm × 8 in.

Supelco

551384

Formamide solution

Chloroform solution NMR reference standard, 1% in acetone-d6 (99,9 atom % D), TMS 0.1 %, NMR tube size 5 mm × 8 in.

Supelco

612979

Chloroform solution

Towards beyond-1 GHz solution NMR: Internal 2H lock operation in an external current mode.
Yanagisawa Y, et al.
Journal of Magnetic Resonance, 192(2), 329-337 (2008)
Rogers Ribeiro et al.
Biodegradation, 24(2), 269-278 (2012-08-23)
Because benzene, toluene, ethylbenzene, and xylenes (BTEX) and ethanol are important contaminants present in Brazilian gasoline, it is essential to develop technology that can be used in the bioremediation of gasoline-contaminated aquifers. This paper evaluates the performance of a horizontal-flow
Bundesgesundheitsblatt, Gesundheitsforschung, Gesundheitsschutz, 55(9), 1192-1200 (2012-09-01)
The German Working Group on Indoor Guidelines of the Federal Environment Agency and the States' Health Authorities is issuing indoor air guide values to protect public health. No human studies are available for health evaluation of ethylbenzene in indoor air.
João Carlos Fraga da Rosa et al.
Environmental monitoring and assessment, 185(7), 5883-5890 (2012-11-10)
The gas station attendants are exposed daily to chemical agents that compose gasoline, such as BTEX (benzene, toluene, ethylbenzene, and xylene), and the exposure to these agents can cause a variety of effects on the human health. Among the various
T Tunsaringkarn et al.
The international journal of occupational and environmental medicine, 3(3), 117-125 (2012-10-02)
Gasoline station workers are exposed to volatile organic compounds such as benzene, toluene, ethylbenzene and xylene (BTEX). To determine the level of exposure to BTEX compounds among gasoline station workers and measure the roadside concentrations of these compounds in the

Articoli

Sigma-Aldrich.com provides an informational article regarding the use of stable, labeled isotopes as NMR reference standards.

Protocolli

ASTM D6526: GC Analysis of Impurities in Toluene on SLB®-IL100, 60 m Column

GC Analysis of Xylene Isomers on SLB®-IL60

-1,3-Dimethylcyclopentane; 1,1-Dimethylcyclopentane; 2,2,3-Trimethylpentane; 2,2-Dimethylbutane; 2,2-Dimethylhexane; 2,2-Dimethylpentane; 2,3-Dimethylbutane; 2,3-Dimethylhexane; 2,4-Dimethylheptane; 2,4-Dimethylpentane; 2,5-Dimethylheptane; 2-Methylhexane; 2-Methylpentane; 3,3-Dimethylpentane; 3,4-Dimethylhexane; 3-Ethylpentane; 3-Methyloctane; 4-Methylheptane; Ethylbenzene; Ethylcyclopentane; 2,6-Dimethylheptane; 3-Ethylheptane

Vedi tutto

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.