267163
Platinum
wire, diam. 0.127 mm, 99.99% trace metals basis
Sinonimo/i:
Platinum element, Platinum gray
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Livello qualitativo
Saggio
99.99% trace metals basis
Forma fisica
wire
Resistività
10.6 μΩ-cm, 20°C
Diametro
0.127 mm
P. eboll.
3827 °C (lit.)
Punto di fusione
1772 °C (lit.)
Densità
21.45 g/cm3 (lit.)
Stringa SMILE
[Pt]
InChI
1S/Pt
BASFCYQUMIYNBI-UHFFFAOYSA-N
Applicazioni
Platinum wire may be used as an electrode during various electrochemical studies. It may also be used during the solid state deposition of colorless transparent crystals of a noncentrosymmetric hexaborate, KBOC, on it surface. Platinum wire, as a catalyst may be useful in accelerating the generation of hydrogen from Ni-rich magnesium alloy in NaCl solution.
Quantità
270 mg = 100 cm; 1.3 g = 500 cm
Codice della classe di stoccaggio
13 - Non Combustible Solids
Classe di pericolosità dell'acqua (WGK)
nwg
Punto d’infiammabilità (°F)
Not applicable
Punto d’infiammabilità (°C)
Not applicable
Scegli una delle versioni più recenti:
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
Wire-like charge transport at near constant bridge energy through fluorene oligomers.
Proceedings of the National Academy of Sciences of the USA, 102(10), 3540-3545 (2005)
Evaluation of a new hydrogen generating system: Ni-rich magnesium alloy catalyzed by platinum wire in sodium chloride solution.
Materials Transactions, 46(12), 2704-2708 (2005)
K3B6O10Cl: a new structure analogous to perovskite with a large second harmonic generation response and deep UV absorption edge.
Journal of the American Chemical Society, 133(20), 7786-7790 (2011)
Journal of nanoscience and nanotechnology, 13(5), 3627-3633 (2013-07-19)
Platinum nanoparticles (Pt NPs) were chemically deposited on a Nafion polymer electrolyte membrane by the impregnation-reduction (I-R) procedure to prepare an active electrode for solid electrochemical sensors. Various analysis methods such as SEM, EDX, XRD and cyclic voltammogram (CV) measurements
Materials science & engineering. C, Materials for biological applications, 33(4), 1907-1913 (2013-03-19)
In this paper a platinum (Pt) nanoparticle decorated graphene (GR) nanosheet was synthesized and used for the investigation on direct electrochemistry of myoglobin (Mb). By integrating GR-Pt nanocomposite with Mb on the surface of carbon ionic liquid electrode (CILE), a
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.