跳转至内容
Merck
  • On-line monitoring of continuous flow chemical synthesis using a portable, small footprint mass spectrometer.

On-line monitoring of continuous flow chemical synthesis using a portable, small footprint mass spectrometer.

Journal of the American Society for Mass Spectrometry (2014-08-12)
Tony W T Bristow, Andrew D Ray, Anne O'Kearney-McMullan, Louise Lim, Bryan McCullough, Alessio Zammataro
摘要

For on-line monitoring of chemical reactions (batch or continuous flow), mass spectrometry (MS) can provide data to (1) determine the fate of starting materials and reagents, (2) confirm the presence of the desired product, (3) identify intermediates and impurities, (4) determine steady state conditions and point of completion, and (5) speed up process optimization. Recent developments in small footprint atmospheric pressure ionization portable mass spectrometers further enable this coupling, as the mass spectrometer can be easily positioned with the reaction system to be studied. A major issue for this combination is the transfer of a sample that is representative of the reaction and also compatible with the mass spectrometer. This is particularly challenging as high concentrations of reagents and products can be encountered in organic synthesis. The application of a portable mass spectrometer for on-line characterization of flow chemical synthesis has been evaluated by coupling a Microsaic 4000 MiD to the Future Chemistry Flow Start EVO chemistry system. Specifically, the Hofmann rearrangement has been studied using the on-line mass spectrometry approach. Sample transfer from the flow reactor is achieved using a mass rate attenuator (MRA) and a sampling make-up flow from a high pressure pump. This enables the appropriate sample dilution, transfer, and preparation for electrospray ionization. The capability of this approach to provide process understanding is described using an industrial pharmaceutical process that is currently under development. The effect of a number of key experimental parameters, such as the composition of the sampling make-up flow and the dilution factor on the mass spectrometry data, is also discussed.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%
Sigma-Aldrich
甲酸, reagent grade, ≥95%
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
甲酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
2-甲基四氢呋喃, BioRenewable, ReagentPlus®, ≥99.5%, contains 150-400 ppm BHT as stabilizer
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
甲酸, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
甲酸, ACS reagent, ≥88%
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
2-甲基四氢呋喃, BioRenewable, anhydrous, ≥99%, Inhibitor-free
Sigma-Aldrich
甲酸, ≥95%, FCC, FG
Sigma-Aldrich
乙腈, ReagentPlus®, 99%
Sigma-Aldrich
乙腈, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%, poly-coated bottles
Supelco
乙腈, HPLC grade, ≥99.93%
Sigma-Aldrich
乙腈, ≥99.8%, suitable for HPLC
Sigma-Aldrich
甲酸, JIS special grade, ≥98.0%
Supelco
乙腈, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
2-甲基四氢呋喃, BioRenewable, anhydrous, ≥99.0%, contains 250 ppm BHT as stabilizer
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) formic acid, suitable for HPLC
USP
二类残留溶剂 - 甲醇, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
甲酸 溶液, BioUltra, 1.0 M in H2O
Sigma-Aldrich
乙腈, ≥99.8%, for residue analysis, JIS 300
Supelco
2-甲基四氢呋喃, analytical standard