推荐产品
等級
certified reference material
品質等級
CofA
current certificate can be downloaded
包裝
ampule of 20 mL
製造商/商標名
RTC QCI-233
濃度
100% in H2O
技術
TOC: suitable
應用
environmental
格式
matrix material
儲存溫度
2-30°C
相关类别
一般說明
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
準備報告
This PT sample is packaged as a 20 mL concentrate. The solvent for this sample is water. The PT sample has been autoclaved for preservation.
To prepare solution, partially fill a 1-L volumetric flask with reagent-grade water. Open ampule PE1388 (be careful to avoid cuts on glass) and transfer 10 mL from the ampule into the flask. Fill the volumetric flask to volume with reagent-grade water and mix well. The sample is now ready for immediate analysis. Analyze the solution to determine BOD or CBOD first. If COD and TOC cannot be determined within two hours after sample preparation, an aliquot should be preserved (pH<2) using 0.2 mL of concentrated sulfuric acid per 100 mL. This aliquot should be stored at 4 degrees Celsius and analyzed as soon as possible within the 28-day maximum holding time.
NOTES: For proper oxygen depletion of BOD and CBOD, the sample should be tested in a dilution series. Use a natural surface water or diluted domestic sewage for seeded dilution water and avoid entrainment of air. For analysis of CBOD, the use of a nitrifying inhibitor is recommended. Be sure to determine the "blank" BOD of your seeded dilution water so that the proper seed correction can be made.
To prepare solution, partially fill a 1-L volumetric flask with reagent-grade water. Open ampule PE1388 (be careful to avoid cuts on glass) and transfer 10 mL from the ampule into the flask. Fill the volumetric flask to volume with reagent-grade water and mix well. The sample is now ready for immediate analysis. Analyze the solution to determine BOD or CBOD first. If COD and TOC cannot be determined within two hours after sample preparation, an aliquot should be preserved (pH<2) using 0.2 mL of concentrated sulfuric acid per 100 mL. This aliquot should be stored at 4 degrees Celsius and analyzed as soon as possible within the 28-day maximum holding time.
NOTES: For proper oxygen depletion of BOD and CBOD, the sample should be tested in a dilution series. Use a natural surface water or diluted domestic sewage for seeded dilution water and avoid entrainment of air. For analysis of CBOD, the use of a nitrifying inhibitor is recommended. Be sure to determine the "blank" BOD of your seeded dilution water so that the proper seed correction can be made.
其他說明
Values of analytes vary lot to lot. Some lots may not contain all analytes.
分析物
说明
5-day BOD 5 - 50 mg/L
Carbonaceous BOD (CBOD) 5 - 50 mg/L
Chemical oxygen demand (COD) 5 - 75 mg/
Total organic carbon (TOC) 1 - 50 mg/L
儲存類別代碼
12 - Non Combustible Liquids
水污染物質分類(WGK)
nwg
閃點(°F)
Not applicable
閃點(°C)
Not applicable
其他客户在看
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门