推荐产品
等級
for ion-selective electrodes
品質等級
產品線
Selectophore™
化驗
≥98.0% (AT)
≥98.0%
形狀
solid
SMILES 字串
[K+].Clc1ccc(cc1)[B-](c2ccc(Cl)cc2)(c3ccc(Cl)cc3)c4ccc(Cl)cc4
InChI
1S/C24H16BCl4.K/c26-21-9-1-17(2-10-21)25(18-3-11-22(27)12-4-18,19-5-13-23(28)14-6-19)20-7-15-24(29)16-8-20;/h1-16H;/q-1;+1
InChI 密鑰
SAGICZRAKJSWLD-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般說明
请访问 传感器应用门户网站 了解更多信息。
應用
四(4-氯苯基)硼酸钾被用作亲脂性阴离子站点钠离子荧光光电倍增管。利用石英晶体微天平测定钾含量时,还将其作为压电晶体的涂层。
包裝
无底玻璃瓶。内容物在插入的熔锥内。
法律資訊
Selectophore is a trademark of Merck KGaA, Darmstadt, Germany
訊號詞
Danger
危險聲明
危險分類
Acute Tox. 3 Oral
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
dust mask type N95 (US), Eyeshields, Gloves
其他客户在看
Sensors (Basel, Switzerland), 13(5), 5841-5856 (2013-05-09)
5,10,15,20-Tetraferrocenyl porphyrin, H2TFcP, a simple example of a donor-acceptor system, was tested as ligand for the development of a novel multi-transduction chemical sensors aimed at the determination of transition metal ions. The fluorescence energy transfer between ferrocene donor and porphyrin
Analytical chemistry, 73(19), 4599-4606 (2001-10-19)
A new chronoamperometric method is used to estimate changes in the membrane composition of mobile-site, ionophore-based membranes. The characteristic features of the chronoamperometric curves (initial current, slope, break time) of valinomycin-based, potassium-selective membranes loaded with potassium tetrakis(4-chlorophenyl)borate are correlated with
Sensors (Basel, Switzerland), 13(6), 6936-6945 (2013-05-28)
A flow biosensor for the detection of toxicity in water using the ammonia-oxidizing bacterium (AOB) Nitrosomonas europaea as a bioreceptor and a polymeric membrane ammonium-selective electrode as a transducer is described. The system is based on the inhibition effects of
Sensors (Basel, Switzerland), 13(4), 4367-4377 (2013-04-04)
All-solid-state sensors with polyvinyl chloride (PVC)-based membranes using off-the-shelf N-hydroxysuccinimide (NHS) and succinimide (Succ) ionophores were prepared using DOP (dioctyl phthalate) and NPOE (ortho-nitrophenyloctyl ether) as plasticizers. Good responses were obtained when NHS was used. The potentiometric response of the
Sensors (Basel, Switzerland), 21(4) (2021-03-07)
The metalloporphyrin ligand bearing incorporated anion-exchanger fragment, 5-[4-(3-trimethylammonium)propyloxyphenyl]-10,15,20-triphenylporphyrinate of Co(II) chloride, CoTPP-N, has been tested as anion-selective ionophore in PVC-based solvent polymeric membrane sensors. A plausible sensor working mechanism includes the axial coordination of the target anion on ionophore metal
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.