推荐产品
無菌
non-sterile
品質等級
形狀
powder
成份
agar, 15.0 g/L
beef extract, 10.0 g/L
peptic digest of animal tissue, 10.0 g/L
sodium chloride, 5.0 g/L
製造商/商標名
NutriSelect® Plus
最終pH值
7.8±0.2 (25 °C)
應用
clinical testing
food and beverages
microbiology
適合性
Corynebacterium spp.
應用
Hoyle Medium Base is a highly selective medium used for the isolation and differentiation of Corynebacterium diphtheriae types.
準備報告
Suspend 40 grams in 915 ml distilled water. Heat to boiling to dissolve the medium completely. Sterilize by autoclaving at 15 lbs pressure (121°C) for 15 minutes. Cool to 55°C and aseptically add 50 ml of laked blood and 35 ml of 1.0% Potassium Tellurite Solution. (Cat. No. 17774) Mix well and pour into sterile Petri plates.
腳註
We offer two media types: the superior granulated GranuCult® and the cost-efficient powdered NutriSelect® culture media, depending on your needs.
The designations basic, plus, or prime are added to indicate the quality control level, from basic quality control to standard QC plus to prime for full regulatory compliance.
The designations basic, plus, or prime are added to indicate the quality control level, from basic quality control to standard QC plus to prime for full regulatory compliance.
法律資訊
GRANUCULT is a registered trademark of Merck KGaA, Darmstadt, Germany
NutriSelect is a registered trademark of Merck KGaA, Darmstadt, Germany
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
Cells, 8(12) (2019-12-07)
A phenomenon of endotoxin tolerance where prior exposure of cells to minute amounts of lipopolysaccharide (LPS) causes them to become refractory to a subsequent high-amount endotoxin challenge is well described for innate immune cells such as monocytes/macrophages, but it is
Fish & shellfish immunology, 95, 564-573 (2019-11-11)
Soybean meal is one of the most promising alternatives to replace fishmeal in the aquaculture industry. However, its ingestion triggers an intestinal inflammatory process that compromises fish health and nutrition. Therefore, finding strategies that reduce the deleterious effects of a
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1132, 121816-121816 (2019-11-11)
The reported methods for the estimation of CG are indirect, long and tedious uses solvent extraction which results in lower recoveries due to several co-eluted components. The present study aims to develop and validate a high throughput method for the
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.