跳转至内容
Merck

02659

Supelco

四乙二醇二甲醚

analytical standard

别名:

2,5,8,11,14-五氧杂十五烷, 二甲基四甘醇, 二甲氧基四乙二醇, 双[2-(2-甲氧基乙氧基)乙基]醚, 四甘醇二甲醚

登录查看公司和协议定价


About This Item

线性分子式:
CH3O(CH2CH2O)4CH3
CAS号:
分子量:
222.28
Beilstein:
1760005
EC號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

analytical standard

品質等級

蒸汽密度

7.7 (vs air)

蒸汽壓力

<0.01 mmHg ( 20 °C)

化驗

≥99.7% (GC)

自燃溫度

510 °F

儲存期限

limited shelf life, expiry date on the label

range of application measuring range

≤60 °C

折射率

n20/D 1.432 (lit.)
n20/D 1.432

bp

275-276 °C (lit.)

mp

−30 °C (lit.)

密度

1.009 g/mL at 25 °C (lit.)

應用

environmental

格式

neat

SMILES 字串

COCCOCCOCCOCCOC

InChI

1S/C10H22O5/c1-11-3-5-13-7-9-15-10-8-14-6-4-12-2/h3-10H2,1-2H3

InChI 密鑰

ZUHZGEOKBKGPSW-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

Tetraethylene glycol dimethyl ether is a non-volatile, higher molecular weight glyme solvent.

應用

Tetraethylene glycol dimethyl ether may be used as an analytical reference standard for the quantification of the analyte in water samples using gas chromatography/mass spectrometry technique.

象形圖

Health hazard

訊號詞

Danger

危險聲明

危險分類

Repr. 1B

安全危害

儲存類別代碼

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

水污染物質分類(WGK)

WGK 1

閃點(°F)

276.8 °F - closed cup

閃點(°C)

136 °C - closed cup

個人防護裝備

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Luisa Mayorga Szott et al.
Journal of biomedical materials research. Part A, 96(1), 150-161 (2010-11-26)
Nonspecific protein adsorption, particularly fibrinogen (Fg), is thought to be an initiating step in the foreign body response (FBR) to biomaterials by promoting phagocyte attachment. In previous studies, we therefore prepared radiofrequency glow discharge (ethylene oxide)-like tetraglyme (CH(3)O(CH(2)CH(2)O)(4)CH(3)) coatings adsorbing
Gautam Mishra et al.
Langmuir : the ACS journal of surfaces and colloids, 26(5), 3720-3730 (2009-12-03)
Physical and photolithographic techniques are commonly used to create chemical patterns for a range of technologies including cell culture studies, bioarrays and other biomedical applications. In this paper, we describe the fabrication of chemical micropatterns from commonly used plasma polymers.
Min Zhang et al.
Journal of biomedical materials research. Part A, 89(3), 791-803 (2008-05-23)
Previous studies have showed that radio-frequency plasma deposited tetraglyme coatings greatly reduced fibrinogen adsorption (Gamma(Fg)) from highly diluted plasmas (0.1 and 1%) and subsequent platelet adhesion under static conditions. In this study, the protein resistant properties of tetraglyme were re-examined
Emily E Fenn et al.
Journal of the American Chemical Society, 131(15), 5530-5539 (2009-03-28)
Poly(ethylene) oxide (PEO) is a technologically important polymer with a wide range of applications including ion-exchange membranes, protein crystallization, and medical devices. PEO's versatility arises from its special interactions with water. Water molecules may form hydrogen-bond bridges between the ether
T Huybrechts et al.
Journal of chromatography. A, 922(1-2), 207-218 (2001-08-07)
A recently developed method for the sampling and analysis of volatile organic compounds in air has been evaluated. The system is based on the enrichment of analytes in tetraethylene glycol dimethyl ether or tetraglyme, a water-soluble organic liquid. The subsequent

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门