推荐产品
物種活性
rat
品質等級
製造商/商標名
Milliplex®
assay range
accuracy: 94-119%
sensitivity: 0.3-17 pg/mL
(MinDC)
standard curve range: 0.7-3,000 pg/mL
(IL-1β, TNFα)
standard curve range: 12-50,000 pg/mL
(PAI-1)
standard curve range: 15-60,000 pg/mL
(IL-6, Leptin)
standard curve range: 24-100,000 pg/mL
(Insulin)
standard curve range: 9.8-40,000 pg/mL
(MCP-1)
技術
multiplexing: suitable
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
wet ice
一般說明
MILLIPLEX® Rat Adipokine Magnetic Bead Panel is a seven-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum and plasma samples: IL-1β, IL-6, Insulin, Leptin, MCP-1, PAI-1, and TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Metabolism
特異性
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
應用
- Analytes: IL-1β, IL-6, Insulin, Leptin, MCP-1 (CCL2), PAI-1 (Total), TNFα
- Recommended Sample Type: Rat serum or plasma
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma
- Assay Run Time: Overnight (16-18) hours at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Endocrine; Obesity; Metabolic Disease
特點和優勢
包裝
成分
Rat Adipokine Quality Control 1, 1 vial, lyophilized
Rat Adipokine Quality Control 2, 1 vial, lyophilized
Assay Buffer, 1 bottle, 30 mL
Bead Diluent, 1 vial, 3.5 mL
Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea
Rat Adipokine Detection Antibodies, 1 bottle, 5.5 mL
Streptavidin-Phycoerythrin, 1 bottle, 5.5 mL
Mixing Bottle, 1 bottle
Sample Plate, 96 well format, 1 plate
2 Foil Plate Sealers
儲存和穩定性
其他說明
法律資訊
免責聲明
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects