mixed cellulose esters (MCE) membrane
plain filter
white filter
品質等級
特點
hydrophilic
製造商/商標名
MF-Millipore™
Millipore
參數
18 mL/min-cm2 water flow rate
2 L/min-cm2 air flow rate
75 °C max. temp.
過濾器直徑
142 mm
厚度
150 μm
重量法萃取物
<2%
顏色
white
折射率
n/D 1.51
基質
MF-Millipore™
孔徑
0.22 μm pore size
75 % porosity
容量
150 μg/cm2 binding capacity (protein)
起泡點
≥3.52 bar, air with water at 23 °C
運輸包裝
ambient
一般說明
Filter Code: GSTF
Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore membrane filters one of the most widely used membranes in analytical and research applications.
MF-Millipore filters without Triton surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore filters.
Features & Benefits:
- Versatile filter for biological and environmental monitoring applications
- Available in a range of pore sizes, colored black or white, with or without a gridded surface
- Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
MF-Millipore filters without Triton surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore filters.
Features & Benefits:
- Versatile filter for biological and environmental monitoring applications
- Available in a range of pore sizes, colored black or white, with or without a gridded surface
- Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
應用
- Biological solutions
- Cell contact
- Very small volumes requiring surfactant-free surfaces
- Isolation of virus-like particles in wastewater
- Microplastics analysis grade water
- Nucleic acid binding, including eDNA
其他說明
Directions for Use
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: General laboratory filtration
- Intended Use: Retention or removal of biological contaminants
- Instructions for Use: Sterilizing filtration of a liquid through a membrane with a 0.2 μm (or smaller) pore size effectively removes biological contaminants, including bacteria, mold and yeast. For the selective retention of larger biological contaminents, liquid filtration through membranes with 0.45 μm (or larger) pore sizes may be used to trap and support microorganism growth for subsequent culture and analysis
- Storage Statement: Store in dry location away from heat source
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
法律資訊
MF-Millipore is a trademark of Merck KGaA, Darmstadt, Germany
Triton is a trademark of The Dow Chemical Company or an affiliated company of Dow
訊號詞
Danger
危險聲明
危險分類
Flam. Sol. 1
儲存類別代碼
4.1B - Flammable solid hazardous materials
水污染物質分類(WGK)
WGK 3