跳转至内容
Merck
所有图片(1)

Key Documents

I-026

Supelco

Interference Mix 4 (For Qualitative Use Only)

5-100 μg/mL each component in methanol, Cerilliant®

别名:

Qualitative Interference Mixture

登录查看公司和协议定价


About This Item

分類程式碼代碼:
41116107
NACRES:
NA.24

等級

analytical standard

形狀

liquid

成份

Alprazolam, 100 μg/mL
Cimetidine, 100 μg/mL
Citalopram hydrobromide, 100 μg/mL (as free base)
Clonazepam, 100 μg/mL
Clopidogrel bisulfate, 100 μg/mL (as free base)
Dextromethorphan, 50 μg/mL
Fluconazole, 100 μg/mL
Hydrochlorothiazide, 100 μg/mL
Lamotrigine, 100 μg/mL
Methylphenidate hydrochloride, 100 μg/mL (as free base)
Omeprazole, 100 μg/mL
L-Thyroxine, 5 μg/mL

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

drug control

psicótropo (Spain); Decreto Lei 15/93: Tabela IV/IIB (Portugal)

濃度

5-100 μg/mL each component in methanol

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

forensics and toxicology

格式

single component solution

儲存溫度

−20°C

正在寻找类似产品? 访问 产品对比指南

一般說明

A multi-component solution standard of routinely monitored over-the-counter (OTC) and prescription drugs alprazolam; cimetidine; citalopram HBr; clonazepam; clopidogrel bisulfate; dextromethorphan; fluconazole; hydrochlorothiazide; lamotrigine; L-thyroxine; methylphenidate HCl; and omeprazole. This standard is for qualitative use only in the evaluation of interferences between the mix components and target analytes of interest in a testing laboratory′s analytical methods.

應用


  • VOCs Determination in Complex Mixtures: Metal oxide-based gas sensor arrays enhanced with machine learning, utilizing Interference Mix 4 for calibration and validation, revolutionize volatile organic compounds analysis in biotechnological applications (Singh et al., 2024).

  • Ammonia Sensing Technology: Development of a highly sensitive ammonia sensor using a PMMA/PANI microwire structure, where Interference Mix 4 serves to test interference resilience, pivotal for maintaining lab environment quality in pharma research (Cheng et al., 2024).

  • Anticoagulant Interference in Medical Testing: Simplified method for removing direct oral anticoagulant interference in mechanical coagulation test systems, employing Interference Mix 4 to validate the approach, essential for accurate clinical diagnostics in medical biotechnology (Exner et al., 2024).

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes,Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门