推荐产品
用途
10 reactions
存貨情形
not available in Japan
儲存溫度
2-8°C
一般說明
AnteoTech identified the following problems that researchers are having with their multiplex assays:
From these findings, they developed the AnteoBind™ Activation Kit For Multiplex Microspheres that is for use with the Luminex xMAP® system and contains the patented AnteoBind Activation Reagent.
With this Activation Kit, you can couple multiple antibodies without extra optimization for each, saving assay development time and reducing the barriers of assay transfer between diverse platforms.
AnteoBind is water based and replaces the dry chemicals you would use with the EDC method. Using AnteoBind instead of NHS/EDC chemistry can save up to 3-4 hours of lab time. Experiments have shown increased stability and functionality for antibodies and a decreased background. AnteoBind improves reproducibility between experiments by providing uniformity between surfaces. You can store your AnteoBind activated microspheres for up to 1 year.
POSTER: A Novel User Friendly Chemistry to Couple Antibodies and Challenging Proteins to Luminex MagPlex Microspheres
- Binding difficult antibodies and antigens to microspheres
- Complex protocols for inexperienced users
- Lengthy microsphere and protein preparation times prior to protein coupling
- Reproducibility between batches of protein coupled microspheres
- Limited storage of ready-to-couple microspheres
From these findings, they developed the AnteoBind™ Activation Kit For Multiplex Microspheres that is for use with the Luminex xMAP® system and contains the patented AnteoBind Activation Reagent.
With this Activation Kit, you can couple multiple antibodies without extra optimization for each, saving assay development time and reducing the barriers of assay transfer between diverse platforms.
AnteoBind is water based and replaces the dry chemicals you would use with the EDC method. Using AnteoBind instead of NHS/EDC chemistry can save up to 3-4 hours of lab time. Experiments have shown increased stability and functionality for antibodies and a decreased background. AnteoBind improves reproducibility between experiments by providing uniformity between surfaces. You can store your AnteoBind activated microspheres for up to 1 year.
POSTER: A Novel User Friendly Chemistry to Couple Antibodies and Challenging Proteins to Luminex MagPlex Microspheres
應用
Activation and coupling of Luminex Microspheres for Multiplex Immunoassays
特點和優勢
- Water based AnteoBind™ activation and coupling reagent for microspheres
- Fast assay development time making it easy to move your ELISA assay to the Luminex xMAP® system
- Compatible with both Luminex MagPlex® and MicroPlex® microspheres
- Test problematic proteins on xMAP, including those cited as not suitable for the system
- An alternative to traditional chemistries such as NHS/EDC methods with an easier to use AnteoBind protocol
- Ease of use, simply pipette AnteoBind Reagent to your chosen microspheres to activate
- Reduce reagent preparation time by 3-4 hours
- Increase antibody functionality
- Low background noise
- High reproducibility between experiments
法律資訊
Anteobind is a trademark of AnteoTech Ltd
MagPlex is a registered trademark of Luminex Corp
MicroPlex is a registered trademark of Luminex Corp
xMAP is a registered trademark of Luminex Corp
仅试剂盒组分
产品编号
说明
- Mix&Go Activation Reagent
- Coupling Buffer
- Storage Buffer
- Low Binding Microcentrifuge Tubes
訊號詞
Warning
危險聲明
危險分類
Aquatic Chronic 2 - Skin Sens. 1
儲存類別代碼
12 - Non Combustible Liquids
閃點(°F)
Not applicable
閃點(°C)
Not applicable
Vaccine, 35(43), 5883-5889 (2017-09-19)
Worldwide about 1.5 million clinical cases of hepatitis A virus (HAV) infections occur every year and increasingly countries are introducing HAV vaccination into the childhood immunization schedule with a single dose instead of the originally licenced two dose regimen. Diagnosis
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门