HADK2MAG-61K
MILLIPLEX® Human Adipokine Magnetic Bead Panel 2 - Endocrine Multiplex Assay
The Human Adipokine Magnetic Bead Panel 2, using the Luminex xMAP technology, enables the simultaneous analysis of nine protein biomarkers in human serum and plasma samples.
About This Item
Produits recommandés
Niveau de qualité
Espèces réactives
human
Fabricant/nom de marque
Milliplex®
assay range
accuracy: 87%
(IL-8)
accuracy: 91%
(TNFα)
accuracy: 94%
(Insulin)
standard curve range: 0.64-10,000 pg/mL
(IL-8)
standard curve range: 0.64-10,000 pg/mL
(NGF)
standard curve range: 0.64-10,000 pg/mL
(TNF-α)
standard curve range: 0.96-15,000 pg/mL
(IL-6)
standard curve range: 1.3-20,000 pg/mL
(IL-1β)
standard curve range: 1.3-20,000 pg/mL
(MCP-1)
standard curve range: 38-600,000 pg/mL
(Leptin)
standard curve range: 9.6-150,000 pg/mL
(HGF)
standard curve range: 9.6-150,000 pg/mL
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-1β)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-8)
inter-assay cv: <15%
intra-assay cv: <10%
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(Leptin)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(NGF)
inter-assay cv: <20%
intra-assay cv: <10%
(TNFα)
Technique(s)
multiplexing: suitable
Méthode de détection
fluorometric (Luminex xMAP)
Conditions d'expédition
wet ice
Catégories apparentées
Description générale
The MILLIPLEX® Human Adipokine Panel 2 is a 9-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum or plasma samples: HGF, IL-1β, IL-6, IL-8, Insulin, Leptin, MCP-1, NGF and TNF-α. This kit uses a 96-well format, contains a lyophilized standard cocktail, 2 quality controls and can measure up to 38 samples in duplicate.
Panel Type: Metabolism
Spécificité
Each antibody pair in a panel is highly specific and displays insignificant cross-reactivity to other analytes in the panel.
Application
- Analytes: IL-1β, IL-6, IL-8, Insulin, Leptin, MCP-1, NGF, TNF-α
- Recommended Sample Type: Human serum and plasma
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma
- Assay Run Time: Overnight (16-18 hours) at 2-8°C
- Research Category: Metabolism
- Research Subcategory: Endocrine
Caractéristiques et avantages
Conditionnement
Stockage et stabilité
Autres remarques
Informations légales
Clause de non-responsabilité
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Code de la classe de stockage
6.1C - Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Classe de danger pour l'eau (WGK)
WGK 3
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Contenu apparenté
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique