03-0184-00
SMC® Human Phospho-Tau (T181) High Sensitivity Immunoassay Kit
Synonyme(s) :
pTau T181 Single Molecule Counting Kit, pTau T181 immunoassay kit, pTau T181 ultra-sensitive immunoassay, pTau Thr181 immunoassay kit
About This Item
Produits recommandés
Fabricant/nom de marque
SMC®
Niveau de qualité
assay range
sensitivity: 0.94 pg/mL
(Lower Limit of Quantification: )
inter-assay cv: ≤12%
intra-assay cv: ≤7%
(five normal plasma samples run in triplicate by 3 different operators on 3 different days.)
Technique(s)
single molecule counting: suitable
Température de stockage
2-8°C
Description générale
Assay protocols are similar to existing sandwich ELISA methods with two key differences:
1) Elution buffer disrupts the sandwich, separating the labeled detection antibody for quantification.
2) The Erenna and SMCxPRO® immunoassay systems detect analytes using Single Molecule Counting (SMC®) technology.
Spécificité
Specificity was not tested.
Cross Reactivity:
Cross-reactivity was not tested.
Accuracy:
- Minimum of 5 serum samples spiked with average recovery of 97% with a range of 70-138%
- Minimum of 5 plasma samples spiked with average recovery of 97% with a range of 81-127%
- Minimum of 5 CSF samples spiked with average recovery of 108% with a range of 82-146%
Application
This new streamline kit has the following features including:
- Improved options for sample prep and incubation
- Lyophilization of the standard provides the kit at one storage condition
- Removal of a plate transfer step
- Increased reagent volumes to accommodate automation
- Validated to run on both SMCxPRO® and Erenna
Research Category:
- Neuroscience
- Neurological
Research Sub-Category:
- Alzheimer′s Disease
- Aging
- Nervous System
- Neurodegenerative Diseases
- Neurofilament & Neuron Metabolism
- Neuronal & Glial Markers
- Neuroregenerative Medicine
- Neuroscience
Conditionnement
Composants
- Assay Buffer
- pTau T181 Coated Beads
- Standard Diluent
- pTau T181 Detection Antibody
- pTau T181 Standard
- 10X Wash Buffer
- Buffer D
- Elution Buffer B
Informations légales
Clause de non-responsabilité
Mention d'avertissement
Danger
Mentions de danger
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B - STOT RE 2 Inhalation
Organes cibles
Respiratory Tract
Code de la classe de stockage
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Contenu apparenté
Discover how to expand neuroscience biomarker research with high sensitivity immunoassays, such as Single Molecule Counting (SMC®) assays. These assays give researchers the tools they need to detect low-abundant blood-based biomarkers and expand biomarker options in neuroscience research.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique