Saltar al contenido
Merck
Todas las fotos(1)

Key Documents

KGW9A3THH1

Millipore

Polysep II 2.0/1.2 µm nominal, Opticap® XLT Capsule

inlet connection diam. 5/8 in., Opticap® XLT 30, pore size 2.0/1.2 μm, cartridge nominal length 30 in. (75 cm)

Sinónimos:

Opticap XLT30 Polysep II 2.0/1.2 μm 5/8 in. HB

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Código UNSPSC:
23151806
eCl@ss:
32031610

Materiales

borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal

Nivel de calidad

cumplimiento norm.

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

esterilidad

non-sterile

Compatibilidad de esterilización

autoclavable compatible

Línea del producto

Opticap® XLT 30

Características

hydrophilic

fabricante / nombre comercial

Opticap®

Parámetros

1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

técnicas

prefiltration: suitable

Longitud

87.1 cm (34.3 in.)

longitud nominal del cartucho

30 in. (75 cm)

filtración área

1.38 m2

diám. conexión a entrada

5/8 in.

An entrada a salida

19.8 cm (7.8 in.)

diám. conexión a salida

5/8 in.

impurezas

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

extraíbles gravimétricos

≤435 mg/capsule

matriz

Polysep II

pore size

2.0/1.2 μm nominal pore size
2.0/1.2 μm pore size

entrada

sample type liquid

Adaptador

inlet hose barb
outlet hose barb
(16 mm (5?8 in.) Hose Barb Inlet and Outlet)

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Device Configuration: Capsule
T-line/Gauge Port: T-line

Características y beneficios

Format: Double Layer

Envase

Double Easy-Open bag

Otras notas

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to the first page of Visual Inspection Guide and introduction section of the Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer to the Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Nota de preparación

Sterilization Method
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Nota de análisis

Gravimetric Extractables: after a 15 L flush and 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L

Información legal

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
Polysep is a trademark of Sigma-Aldrich Co. LLC

¿No encuentra el producto adecuado?  

Pruebe nuestro Herramienta de selección de productos.

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 2


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico