1.02136
Contact C
Envirocheck™, Contact Total Coliforms/E.Coli coated with Plate Count Agar and Chromocult Coliform Agar
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización
About This Item
Código UNSPSC:
41116116
NACRES:
NA.74
Productos recomendados
Materiales
plastic cap
plastic slide
plastic tube
Nivel de calidad
Línea del producto
Envirocheck™
Formulario
solid (ready-to-use)
fabricante / nombre comercial
Envirocheck™
aplicaciones
food and beverages
surface monitoring
water monitoring
temp. de almacenamiento
2-30°C
idoneidad
Escherichia coli (total count)
coliforms
Categorías relacionadas
Descripción general
(total coliforms/E.coli) Envirocheck™
Envirocheck Contact Total Coliforms/E.Coli, a semi-quantitative detection of coliform bacteria on surfaces and in liquids, are flexible paddles that are coated with Plate Count Agar for simultaneous detection of coliforms and E. coli.Slide A is coated with Plate Count Agar to obtain the total viable (aerobic) count. Slide B is coated with Chromocult Coliform Agar for the simultaneous detection of coliforms and E. coli in water and food-samples.
Aplicación
This medium is recommended for the simultaneous detection of coliforms and E. coli in water and food-samples. Envirocheck contact slides can be used for both surface and liquid testing in industrial and environmental monitoring.
Nota de análisis
Count the number of colonies on both sides of the paddle. Plate Count Agar: Count the number of colonies for obtaining the total aerobic bacterial count (TVC). Chromocult Coliform Agar: Count the number of dark-blue to violet colonies (E. coli) and the number of salmon to red colonies for other coliforms. Additionally, E. coli can be confirmed by adding KOVAC′s Indole Reagent directly onto the colony (positive indole reaction: red colour).
Sterility: passes test
pH-value/side one (25 °C): 6.7 - 7.3
pH-value/side two (25 °C): 6.5 - 7.1
Growth/side one
- Escherichia coli ATCC 11775 (WDCM 00090):
good
- Escherichia coli O157:H7 ATCC 35150: good
- Citrobacter freundii ATCC 8090: good
- Salmonella enteritidis ATCC 13076 (WDCM 00030): good
Growth/side two
- Escherichia coli ATCC 11775 (WDCM 00090):
good
- Escherichia coli O157:H7 ATCC 35150: fair/good
- Citrobacter freundii ATCC 8090: good
- Salmonella enteritidis ATCC 13076 (WDCM 00030): good
Colonies
- Escherichia coli ATCC 11775 (WDCM 00090):
dark blue to violet
- Escherichia coli O157:H7 ATCC 35150: salmon to red
- Citrobacter freundii ATCC 8090: salmon to red
- Salmonella enteritidis ATCC 13076 (WDCM 00030): colourless
Incubation: 48 hrs.; 35 °C; aerobic.
pH-value/side one (25 °C): 6.7 - 7.3
pH-value/side two (25 °C): 6.5 - 7.1
Growth/side one
- Escherichia coli ATCC 11775 (WDCM 00090):
good
- Escherichia coli O157:H7 ATCC 35150: good
- Citrobacter freundii ATCC 8090: good
- Salmonella enteritidis ATCC 13076 (WDCM 00030): good
Growth/side two
- Escherichia coli ATCC 11775 (WDCM 00090):
good
- Escherichia coli O157:H7 ATCC 35150: fair/good
- Citrobacter freundii ATCC 8090: good
- Salmonella enteritidis ATCC 13076 (WDCM 00030): good
Colonies
- Escherichia coli ATCC 11775 (WDCM 00090):
dark blue to violet
- Escherichia coli O157:H7 ATCC 35150: salmon to red
- Citrobacter freundii ATCC 8090: salmon to red
- Salmonella enteritidis ATCC 13076 (WDCM 00030): colourless
Incubation: 48 hrs.; 35 °C; aerobic.
Información legal
ENVIROCHECK is a trademark of Merck KGaA, Darmstadt, Germany
Código de clase de almacenamiento
11 - Combustible Solids
Clase de riesgo para el agua (WGK)
WGK 2
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico