Direkt zum Inhalt
Merck

PHR1555

Supelco

Hexan

Pharmaceutical Secondary Standard; Certified Reference Material

Synonym(e):

Hexan, n-Hexan

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
CH3(CH2)4CH3
CAS-Nummer:
Molekulargewicht:
86.18
Beilstein:
1730733
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
41116107
PubChem Substanz-ID:
NACRES:
NA.24

Qualität

certified reference material
pharmaceutical secondary standard

Qualitätsniveau

Agentur

traceable to USP 1601601

Dampfdichte

~3 (vs air)

Dampfdruck

256 mmHg ( 37.7 °C)
5.2 psi ( 37.7 °C)
~132 mmHg ( 20 °C)

Analysenzertifikat (CofA)

current certificate can be downloaded

Selbstzündungstemp.

453 °F

Expl.-Gr.

7.7 %

Verpackung

ampule of 3x1.2 mL

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

Brechungsindex

n20/D 1.375 (lit.)

bp

69 °C (lit.)

mp (Schmelzpunkt)

−95 °C (lit.)

Dichte

0.659 g/mL at 25 °C (lit.)

Anwendung(en)

pharmaceutical (small molecule)

Format

neat

Lagertemp.

2-30°C

SMILES String

CCCCCC

InChI

1S/C6H14/c1-3-5-6-4-2/h3-6H2,1-2H3

InChIKey

VLKZOEOYAKHREP-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Hexane is a non-polar organic solvent and a straight-chain alkane with six carbon atoms. It belongs to the Class 2 category of organic solvents, as per United States Pharmacopoeia. It has limited application in the synthesis of pharmaceuticals, due to its moderate toxicity.
Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.

Anwendung

Hexane may be used as a pharmaceutical reference standard for the determination of the analyte in bulk drug and pharmaceutical formulations by gas chromatography.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Hinweis zur Analyse

These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.

Sonstige Hinweise

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Fußnote

To see an example of a Certificate of Analysis for this material enter LRAB5023 in the slot below. This is an example certificate only and may not be the lot that you receive.

Empfohlene Produkte

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Signalwort

Danger

Gefahreneinstufungen

Aquatic Chronic 2 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

Zielorgane

Central nervous system, Nervous system

Lagerklassenschlüssel

3 - Flammable liquids

WGK

WGK 3

Flammpunkt (°F)

-7.6 °F - closed cup

Flammpunkt (°C)

-22 °C - closed cup


Choose from one of the most recent versions:

Analysenzertifikate (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Slide 1 of 2

1 of 2

?467? Residual Solvents
USP43/NF38: United States Pharmacopeia and National Formulary
United States Pharmacopeia/National Formulary, 45(3)(9), 6712-6712 (2019)
Green process chemistry in the pharmaceutical industry
Cue BW and Zhang J
Green Chemistry Letters and Reviews, 2(4), 193-211 (2009)
What is a green solvent? A comprehensive framework for the environmental assessment of solvents
Capello C, et al.
Green Chemistry, 9(9), 927-934 (2007)
A generic static headspace gas chromatography method for determination of residual solvents in drug substance.
Cheng, et al.
Journal of Chromatography A, 1217(41), 6413-6421 (2010)

Protokolle

Separation of Hexane; Heptane; Octane; Nonane; Decane; Undecane; Dodecane; Tetradecane; Hexadecane; Octadecane; Eicosane; Tetracosane; Octacosane; Dotriacontane; Hexatriacontane; Tetracontane; Tetratetracontane

GC Analysis of Class 2 Residual Solvents on OVI-G43

Protocol for GC Analysis of Hydrocarbons in Gasoline on Petrocol® DH

-Xylene; Nonane; Propylbenzene; Mesitylene; 1,2,4-Trimethylbenzene; 1,2,3-Trimethylbenzene; 1,3-Diethylbenzene; 1,4-Dimethyl-2-ethylbenzene; 1,2-Dimethyl-4-ethylbenzene; Durene; 1,2,3,5-Tetramethylbenzene; 1,2,3,5-Tetramethylbenzene; 2-Methylnaphthalene (β)

Alle anzeigen

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.