Direkt zum Inhalt
Merck

HANG2MAG-12K

Millipore

MILLIPLEX® Human Angiogenesis Panel 2, HANG2MAG-12K

Angiogenesis Bead-Based Multiplex Assays using the Luminex technology enables the simultaneous analysis of multiple angiogenic biomarkers in human serum, plasma and cell culture samples.

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
12161503
eCl@ss:
32161000
NACRES:
NA.84

Qualitätsniveau

Speziesreaktivität

human

Hersteller/Markenname

Milliplex®

assay range

accuracy: 88-97%
standard curve range: 137-100,000 pg/mL
(Thrombospondin-2)

standard curve range: 137-100,000 pg/mL
(sVEGFR2)

standard curve range: 137-100,000 pg/mL
(suPAR)

standard curve range: 14-10,000 pg/mL
(sAXL)

standard curve range: 14-10,000 pg/mL
(sHER3)

standard curve range: 14-10,000 pg/mL
(sVEGFR1)

standard curve range: 27-20,000 pg/mL
(sIL-6Rα)

standard curve range: 27-20,000 pg/mL
(sPECAM-1)

standard curve range: 27-20,000 pg/mL
(sTIE-2)

standard curve range: 274-200,000 pg/mL
(Angiostatin)

standard curve range: 274-200,000 pg/mL
(sE-Selectin)

standard curve range: 274-200,000 pg/mL
(sNeuropilin-1)

standard curve range: 41-30,000 pg/mL
(Osteopontin (OPN))

standard curve range: 41-30,000 pg/mL
(sEGFR)

standard curve range: 41-30,000 pg/mL
(sHER2)

standard curve range: 41-30,000 pg/mL
(sc-Kit/sSCFR)

standard curve range: 412-300,000 pg/mL
(sVEGFR3)

standard curve range: 69-50,000 pg/mL
(sHGFR)

standard curve range: 7-5,000 pg/mL
(PDGF-AB/BB)

Methode(n)

multiplexing: suitable

Nachweisverfahren

fluorometric (Luminex xMAP)

Versandbedingung

wet ice

Allgemeine Beschreibung

Angiogenesis, the development of new vascular networks, is a key process in normal growth and development as well as in wound healing, with homeostasis maintained by a delicate balance of angiogenic factors and inhibitors. Consequently, insufficient, or excessive blood vessel growth underlies many diseases, including cardiovascular disease, diabetic ulcers, macular degeneration, and cancer. Angiogenesis plays a significant role in tumor growth and metastasis.

MILLIPLEX® Human Angiogenesis Magnetic Bead Panel 2 is a 19-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma, cell culture samples, and tissue homogenates/lysates: Angiostatin, soluble E-Selectin, (sE-Selectin), Osteopontin (OPN), Platelet Derived Growth Factor-AB/BB (PDGF-AB/BB), soluble Platelet Endothelial Cell Adhesion Molecule-1 (sPECAM-1), Thrombospondin-2 (TSP-2), soluble AXL (sAXL), soluble c-Kit/Stem Cell Growth Factor Receptor (sc-Kit/SCFR), soluble Epidermal Growth Factor Receptor (sEGFR)†, soluble Human Epidermal Growth Factor Receptor 2 (sHer2), soluble Human Epidermal Growth Factor Receptor 3 (sHer3), soluble Hepatocyte Growth Factor Receptor/c-Met (sHGFR/c-Met), soluble IL-6Rα, soluble Neuropilin-1 (sNRP-1), soluble Tie-2 (sTie-2), soluble Urokinase-type Plasminogen Activator Receptor (suPAR), soluble Vascular Endothelial Growth Factor Receptor 1 (sVEGFR1), soluble Vascular Endothelial Growth Factor Receptor 2 (sVEGFR2), and soluble Vascular Endothelial Growth Factor Receptor 3 (sVEGFR3). This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

†Antibody against active site results in preferential binding to unbound EGFR.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Circulating Cancer

Anwendung

  • Analytes: Angiostatin, soluble AXL (sAXL) , soluble c-Kit/Stem Cell Growth Factor Receptor (sc-Kit/SCFR), soluble E-Selectin (sE-Selectin), soluble Epidermal Growth Factor Receptor (sEGFR/sErbB1/sHER1)†, soluble Human Epidermal Growth Factor Receptor 2 (sHer2/sHER2/sErbB2), soluble Human Epidermal Growth Factor Receptor 3 (sHer3/ sHER3 / sErbB3), soluble Hepatocyte Growth Factor Receptor (sHGFR/c-Met/sc-Met), soluble IL-6Rα (IL-6Rα (soluble)/sIL-6Rα), soluble Neuropilin-1 (sNRP-1), Osteopontin (OPN), Platelet Derived Growth Factor-AB/BB (PDGF-AB/BB), soluble Platelet Endothelial Cell Adhesion Molecule-1 (sPECAM-1/sCD31), Thrombospondin-2 (TSP-2), soluble Tie-2 (sTie-2), soluble Urokinase-type Plasminogen Activator Receptor (suPAR), soluble Vascular Endothelial Growth Factor Receptor 1 (soluble VEGFR1, sVEGFR1/ sFlt-1), soluble Vascular Endothelial Growth Factor Receptor 2 (soluble VEGFR2/sVEGFR2/ sKDR/sFlk-1), soluble Vascular Endothelial Growth Factor Receptor 3 (soluble VEGFR3/sVEGFR3/ sFlt-4).
  • †Antibody against active site results in preferential binding to unbound EGFR.
  • Recommended Sample Type: Human serum, plasma, cell culture supernatants and tissue/cell homogenates/lysates
  • Recommended Sample Dilution: 25 μL per well of 1:5 diluted plasma or serum; cell culture supernatant may be used undiluted or diluted with appropriate control medium
  • Assay Run Time: Overnight (16-18 hours) at 2-8°C
  • Research Category: Cancer

Leistungsmerkmale und Vorteile

Design your multiplex kit by choosing available analytes within this panel.

Sonstige Hinweise

Please contact Technical Service for linearity of dilution.
Sensitivity: See kit protocol for individual analytes sensitivities.

Rechtliche Hinweise

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Signalwort

Danger

Gefahreneinstufungen

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Zielorgane

Respiratory Tract

Lagerklassenschlüssel

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Sayuri Padayachee et al.
Nigerian journal of physiological sciences : official publication of the Physiological Society of Nigeria, 37(1), 29-34 (2022-08-11)
A dysregulation of angiogenic mediators has been implicated in HIV infection. Inconsistent data exists on highly active antiretroviral therapy (HAART) usage in pregnancy and its association with PE development. In view of the high prevalence of HIV infection and PE
Juan Pablo Hinestrosa et al.
Communications medicine, 2, 29-29 (2022-05-24)
Detecting cancer at early stages significantly increases patient survival rates. Because lethal solid tumors often produce few symptoms before progressing to advanced, metastatic disease, diagnosis frequently occurs when surgical resection is no longer curative. One promising approach to detect early-stage

Verwandter Inhalt

Detection of cancer biomarkers through multiplex cancer assays can accelerate studies of normal homeostasis and tumorigenic processes. See how MILLIPLEX® multiplex cancer assays are advancing various cancer research areas including lung cancer, breast cancer, and immuno-oncology research.

Learn how multiplexing with MILLIPLEX® multiplex assays can help simplify cancer research by measuring multiple circulating biomarkers at once. Find multiplex panels to analyze JAK-STAT, mTOR, MAPK, SAPK, TGFβ signaling pathways, and more.

Learn how immunoassays are used in cosmetics and personal care research to discover potential harmful effects of cosmetics products, and assess markers of inflammation, sensitization, aging, and tissue regeneration among others.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.