Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

G005923

GC Analysis of Polynuclear Aromatic Hydrocarbons (PAHs) in Salmon on SPB®-608 (20 m x 0.18 mm I.D., 0.18 μm) after QuEChERS Cleanup using Supel QuE Z-Sep, Fast GC Analysis

suitable for GC, application for SPE

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

tecniche

gas chromatography (GC): suitable
solid phase extraction (SPE): suitable

Parametri analitici

sample preparation: Dispersive (QuEChERS)
sample/matrix: raw salmon spiked with PAHs at 100 ng/g
extraction process: add 25 mL acetonitrile and the contents of the Supel QuE Non-buffered tube (55294-U); shake for 5 minutes; centrifuge for 5 minutes at 3200 rpm
extraction tube: Supel QuE Non-buffered tube, magnesium sulfate/sodium chloride (55294-U)
clean-up tube: Supel QuE Z-Sep (500 mg, part no. 55299-U), magnesium sulfate (450 mg, part no. 63135) (55299-U, 63135)
clean-up process: transfer 3 mL of acetonitrile layer, Supel QuE Z-Sep (500 mg) and MgSO4 (450 mg) into an extraction tube; (shake 1 minute; centrifuge for 3 minutes at 3400 rpm; remove 1 mL supernatant for GC-MS analysis)
column: SPB-608, 20 m x 0.18 mm I.D. x 0.18 μm
oven: 60 °C (1 min), 25 °C/min to 275 °C, 10 °C/min to 300 °C (13 min)
inj. temp.: 265 °C
detector: MS, SIM
MSD interface: 300 °C
carrier gas: helium, 1.5 mL/min, constant
injection: 1 μL, splitless (1 min)
liner: 4 mm I.D. FocusLiner with taper

Compatibilità

application for SPE

applicazioni

food and beverages

Descrizione generale

Stenerson, K.; Ye, M.; Halpenny, M., New Analytical Tools for the Determination of Persistent Organic Pollutants (POPs) in Fatty Food and Beverage Matrices Using QuEChERS Extraction/Cleanup and Gas Chromatography (GC) Analysis. Pittcon 2013. Sigma-Aldrich/Supelco publication T413034

Applicazioni

Extraction solvent: acetonitrile, 25 mL
Clean-up volume: 3 mL
Clearn-up tube: Supel QuE Z-Sep (500 mg, part no. 55299-U, magnesium sulfate (450 mg, part no. 63135)

Risultati analitici

Sample pretreatment: Place 5 g ground sample into 50 mL centrifuge tube. Spike with 100 ng/g target PAHs and internal standards. Let sit 30 min. Add 5 mL water and homogenize.
This application demonstrates the use of dispersive SPE or QuEChERS for the extraction and cleanup of raw salmon for GC-MS analysis of polynuclear aromatic hydrocarbons (PAHs). Supel QuE Z-Sep sorbent was used in the cleanup step and found to reduce background and yield recoveries >80% for a majority of the PAHs tested.

Note legali

FocusLiner is a trademark of SGE Analytical Science Pty Ltd.
SPB is a registered trademark of Merck KGaA, Darmstadt, Germany
Supel is a trademark of Sigma-Aldrich Co. LLC

Analita

Descrizione

    Naphthalene
    2-Methylnaphthalene (β)
    1-Methylnaphthalene
    Biphenyl
    2,6-Dimethylnaphthalene
    Acenaphthylene
    Acenaphthene
    2,3,5-Trimethylnaphthalene
    Fluorene
    Dibenzothiophene
    Phenanthrene
    Anthracene
    1-Methylphenanthrene
    Fluoranthene
    Pyrene
    Retene
    Benzo[b]fluoranthene
    Benzo[k]fluoranthene
    Benzo[j]fluoranthene
    Benzo[e]pyrene
    Benzo[a]pyrene
    Perylene
    Dibenz[a,h]anthracene
    Benzo[ghi]perylene
    Vedi tutto (24)

Colonnina o piastra per SPE

N° Catalogo
Descrizione
Determinazione del prezzo

Choose from one of the most recent versions:

Certificati d'analisi (COA)

Lot/Batch Number

Sorry, we don't have COAs for this product available online at this time.

If you need assistance, please contact Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.