GE17-5168-01
Mono S® 5/50 GL
About This Item
Prodotti consigliati
ligand
-OCH2CH(OH)CH2OCH2CH(OH)CH2SO3-
Materiali
PEEK column
Descrizione
Ion Exchanger Type (Methyl sulfonate strong cation)
Confezionamento
pkg of 1 mL
Parametri
580 psi
Dimensioni del letto
5 mm × 50 mm
Volume del letto
1 mL
Diam. int. colonna
5.7 mm
Matrice
monodisperse porous polystyrene/divinyl benzene beads
polymeric
Gruppo funzionale matrice
methyl sulfonate phase
Dimens. media delle particelle
10 μm
cleaning
1-14
Intervallo di esercizio
2-12
Tecnica di separazione
cation exchange
Descrizione generale
The Tricorn columns offer high-resolution separations with greater loading capacity but slightly lower resolution than MiniBeads columns.
Caratteristiche e vantaggi
- Monodisperse 10 μm porous beads yield high resolution, dynamic capacity, reproducibility, and durability.
- Maximum resolution is achieved from the efficiency of small, perfectly spherical monodispersed particles optimally packed in columns coupled with the excellent selectivities of the Q ion exchangers.
- Compatible with AKTA design, FPLC™ System, and other high-performance LC systems.
- MonoBeads are also available as Mono P® for chromatofocusing
Stoccaggio e stabilità
Risultati analitici
Altre note
Note legali
Avvertenze
Warning
Indicazioni di pericolo
Consigli di prudenza
Codice della classe di stoccaggio
3 - Flammable liquids
Scegli una delle versioni più recenti:
Certificati d'analisi (COA)
Ci dispiace, ma al momento non ci sono COA disponibili online per questo prodotto.
Se ti serve aiuto, non esitare a contattarci Servizio Clienti
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Articoli
This page provides information about performing an isolation of recombinant protein complexes with different pull-down assays with products from GE Healthcare.
This page shows how to perform a purification of His-tagged membrane proteins.
This page covers the standard ÄKTAdesign configurations for simple IEX chromatography.
This page shows volatile and non-volatile buffer suggestions for anion and cation exchange chromatography.
Protocolli
This page covers using Monobeads for purification of proteins, peptides, or oligonucleotides.
This page shows how to condition membrane proteins for further analysis with products from GE Healthcare.
This page clarifies sample preparation, buffer exchange and desalting, removal of lipoproteins, phenol red, and low molecular weight contaminants in Ion exchange chromatography.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.