Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

QC1130

Supelco

Demand-WP

certified reference material

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
41116107
NACRES:
NA.24

Grado

certified reference material

Livello qualitativo

CdA

current certificate can be downloaded

Confezionamento

ampule of 20 mL

Produttore/marchio commerciale

RTC QCI-026

Concentrazione

100% in H2O

tecniche

TOC: suitable

applicazioni

environmental

Formato

matrix material

Temperatura di conservazione

2-30°C

Descrizione generale

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Applicazioni

Product is suitable for measurement of:
  • Biochemical oxygen demand (BOD)
  • Carbonaceous BOD (CBOD)
  • Chemical oxygen demand (COD)
  • Dissolved organic carbon (DOC)
  • Total organic carbon (TOC)

Nota sulla preparazione

The solvent for this sample is water. This sample is packaged as a 20 mL concentrate. The sample has been autoclaved for preservation.
PREPARATION INSTRUCTIONS
To prepare solution, partially fill a 1-L volumetric flask with reagent-grade water. Open ampule QC1130-20ML (be careful to avoid cuts on glass) and transfer 10 mL from the ampule into the flask. Fill the volumetric flask to volume with reagent-grade water and mix well. The sample is now ready for immediate analysis.
Analyze the solution to determine BOD or CBOD first. If COD and TOC cannot be determined within two hours after sample preparation, an aliquot should be preserved (pH<2) using 0.2 mL of concentrated sulfuric acid per 100 mL. This aliquot should be stored at 4 degrees Celsius and analyzed as soon as possible within the 28-day maximum holding time.
NOTES: For proper oxygen depletion of BOD and CBOD, the sample should be tested in a dilution series. Use a natural surface water or diluted domestic sewage for seeded dilution water and avoid entrainment of air. For analysis of CBOD, the use of a nitrifying inhibitor is recommended. Be sure to determine the “blank” BOD of your seeded dilution water so that the proper seed correction can be made.

Altre note

Values of analytes vary lot to lot. Some lots may not contain all analytes.

Analita

Descrizione

    5-Day BOD 18 - 230 mg/L
    Carbonaceous BOD (CBOD) 18 - 230 mg/L
    Chemical oxygen demand (COD) 30 - 250 mg/L
    Dissolved organic carbon (DOC) 6 - 100 mg/L
    Total organic carbon (TOC) 6 - 100 mg/L

Codice della classe di stoccaggio

12 - Non Combustible Liquids

Classe di pericolosità dell'acqua (WGK)

nwg

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 4

1 of 4

Supelco

Supelco

QC1041

Minerals

Supelco

Supelco

QC1549

Dissolved Oxygen

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.