04973
Micro-Array for Mass Spectrometry (MAMS)
for quantitative MALDI
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Codice UNSPSC:
41115404
Prodotti consigliati
Resistività di superficie
15-25 Ω/sq
tecniche
MALDI-MS: suitable
Lungh. × Largh. × Alt.
75 mm × 25 mm × 1.1 mm
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Descrizione generale
- 8 lanes of 12x2 spots
- spot diameter: 100 μm
- spot depth: ~40 μm
Polysilazane-coated, transparent indium tin oxide target slide, microstructured by picosecond laser ablation with 8 x 2 lanes of 12 sample spots with a diameter of 400 μm and a depth of ~40 μm. Each lane has one reservoir of 1 mm diameter.
Caratteristiche e vantaggi
MAMS represent a type of substrate for MALDI-MS using a combination of hydrophilic reservoirs surrounded by an omniphobic surface for massively parallel, automated sample spotting. The MAMS chip featuring 8x2 lanes of 12 spots is designed for use in quantitative MALDI analysis (qMALDI). The analyte of interest can easily be distributed in MAMS by pulling droplet of analyte solution over the microarray surface with a glass slide or piece of plastic resulting in the generation of very reproducible nanoliter aliquots avoiding the need of a robotic microarray spotter.
The small aliquot reservoirs have been shown to result in a very homogenous crystallization of the matrix-analyte mixture, a prerequisite for using MALDI in a quantitative fashion. Moreover, this miniaturized sample target leads to virtually complete sample consumption upon laser irradiation, and only a few μL of analyte solution are needed for successful analysis.
The small aliquot reservoirs have been shown to result in a very homogenous crystallization of the matrix-analyte mixture, a prerequisite for using MALDI in a quantitative fashion. Moreover, this miniaturized sample target leads to virtually complete sample consumption upon laser irradiation, and only a few μL of analyte solution are needed for successful analysis.
Compatibilità
Compatible with the Bruker Daltonik MTP Slide Adapter II
Prodotti correlati
N° Catalogo
Descrizione
Determinazione del prezzo
Scegli una delle versioni più recenti:
Certificati d'analisi (COA)
Lot/Batch Number
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documenti section.
Se ti serve aiuto, non esitare a contattarci Servizio Clienti
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.