Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

KWSSA3THH1

Millipore

Milligard® 0.5/0.2 µm nominal, Opticap® XLT Capsule

Opticap® XLT 30, inlet connection diam. 5/8 in., pore size 0.5/0.2 μm, cartridge nominal length 30 in. (75 cm)

Sinonimo/i:

Opticap XLT30 Milligard 0.5/0.2 μm 5/8 in. HB/HB

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
23151806
eCl@ss:
32031610

Materiali

mixed cellulose esters (MCE)
polyester support
polypropylene
polypropylene housing
polypropylene vent cap
silicone seal

Livello qualitativo

Conformità normativa

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

Sterilità

non-sterile

Compatibilità con la sterilizzazione

autoclavable compatible

Nome Commerciale

Opticap® XLT 30

Caratteristiche

hydrophilic

Produttore/marchio commerciale

Opticap®

Parametri

1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

tecniche

prefiltration: suitable

Lunghezza

87.1 cm (34.3 in.)

Lunghezza nominale della cartuccia

30 in. (75 cm)

Superficie filtrante

2.07 m2

Diam. connessione ingresso

5/8 in.

Amp. ingresso/ uscita

19.8 cm (7.8 in.)

Diam. connessione uscita

5/8 in.

Impurezze

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Estraibili (gravimetria)

≤165 mg/capsule

Matrice

Milligard®

pore size

0.5/0.2 μm nominal pore size
0.5/0.2 μm pore size

input

sample type liquid

Raccordi

inlet hose barb
outlet hose barb
(16 mm (5?8 in.) Hose Barb Inlet and Outlet)

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Device Configuration: Capsule
T-line/Gauge Port: T-line

Caratteristiche e vantaggi

Format: Double Layer

Confezionamento

Double Easy-Open bag

Altre note

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Specifiche

Filter Grade: Standard Milligard® Media

Nota sulla preparazione

Sterilization Method
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Risultati analitici

Gravimetric Extractables: after 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L

Note legali

MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Non trovi il prodotto giusto?  

Prova il nostro Motore di ricerca dei prodotti.

Codice della classe di stoccaggio

4.1B - Flammable solid hazardous materials

Classe di pericolosità dell'acqua (WGK)

WGK 3


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.