Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

CTGR03TP1

Millipore

Cartuccia Aervent® da 0,2 µm

pore size 0.2 μm, cartridge nominal length 30 in. (76 cm), Code 0 (2-222; O-rings)

Sinonimo/i:

Aervent CTGR Cartridge Filter 30 in. 0.2 µm Code 0

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
23151806
eCl@ss:
32031690

Materiali

PTFE
polypropylene
polypropylene support
silicone seal

Livello qualitativo

Sterilità

non-sterile

Compatibilità con la sterilizzazione

steam-in-place compatible

Nome Commerciale

Aervent®

Caratteristiche

hydrophobic

Produttore/marchio commerciale

Aervent®

Parametri

≤72 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)
1.7 bar max. inlet pressure (25 psi) at 80 °C
1.8 bar max. differential pressure (25 psid) at 80 °C (Forward)
4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)
4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)

tecniche

gas filtration: suitable

Lunghezza

30 in.

Larghezza

2.7 in.

Lunghezza nominale della cartuccia

30 in. (76 cm)

Diametro

6.9 cm (2.7 in.)

Superficie filtrante

1.95 m2

Impurezze

<0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction)

Estraibili (gravimetria)

≤105 mg/cartridge

Matrice

Aervent®

Dimensione pori

0.2 μm pore size

input

sample type gas

Punto di bolla

≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C

Codice cartuccia

Code 0 (2-222; O-rings)

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Device Configuration: Cartridge

Caratteristiche e vantaggi

Rated for aerosol retention of a total challenge of 108–1010 plaque forming units of ΦX-174 virus particles at 85 Nm3/h (50 SCFM) per cartridge.

Confezionamento

Double Easy-Open bag

Qualità

Retains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²

Nota sulla preparazione

Sterilization Method
150 (100 forward/50 reverse) SIP cycles of 30 min @ 145 °C
This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Risultati analitici

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in a 70/30% IPA/water mixture at controlled room temperature
HydroCorr: ≤2.3 mL/min @ 2.6 bar (38 psig) per 30 in cartridge

Altre note

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Note legali

AERVENT is a registered trademark of Merck KGaA, Darmstadt, Germany
ASTM is a registered trademark of American Society for Testing and Materials

Non trovi il prodotto giusto?  

Prova il nostro Motore di ricerca dei prodotti.


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.