Passa al contenuto
Merck
Tutte le immagini(2)

Key Documents

GF12777059

Tantalum

rod, 100mm, diameter 16mm, as drawn, 99.9%

Sinonimo/i:

Tantalum, TA007945, Ta

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula empirica (notazione di Hill):
Ta
Numero CAS:
Peso molecolare:
180.95
Numero MDL:
Codice UNSPSC:
12141741
ID PubChem:
NACRES:
NA.23

Tensione di vapore

<0.01 mmHg ( 537.2 °C)

Saggio

99.90%

Forma fisica

rod

Temp. autoaccensione

572 °F

Produttore/marchio commerciale

Goodfellow 127-770-59

Resistività

13.5 μΩ-cm, 20°C

L × diam.

100 mm × 16 mm

P. eboll.

5425 °C (lit.)

Punto di fusione

2996 °C (lit.)

Densità

16.69 g/cm3 (lit.)

Stringa SMILE

[Ta]

InChI

1S/Ta
GUVRBAGPIYLISA-UHFFFAOYSA-N

Descrizione generale

For updated SDS information please visit www.goodfellow.com.

Note legali

Product of Goodfellow

Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Ci dispiace, ma al momento non ci sono COA disponibili online per questo prodotto.

Se ti serve aiuto, non esitare a contattarci Servizio Clienti

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Robert Cohen
American journal of orthopedics (Belle Mead, N.J.), 31(4), 216-217 (2002-05-15)
Conventional materials used for orthopedic reconstruction implants limit the design of new and improved implants. Solid metal is rigid. Porous fixation surfaces have low volumetric porosity available for biologic ingrowth and low frictional characteristics for initial implant stability and have
J Black
Clinical materials, 16(3), 167-173 (1993-12-09)
A detailed literature search was carried out to define the current knowledge about the biological performance of tantalum. The pure metal appears, to a great degree, to be inert both in vivo and in vitro. Both the pure metal and
Jian Lu et al.
Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery, 26(2), 244-247 (2012-03-13)
To review the progress in the treatment of bone defect by porous tantalum implant. Recent literature was extensively reviewed and summarized, concerning the treatment method of bone defect by porous tantalum implant. By right of their unique properties, porous tantalum
Juncai Deng et al.
Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 28(2), 419-422 (2011-05-25)
This paper describes the biological characteristics of the metal tantalum (Ts) and the application status of tantalum in artificial joints, bone necrosis, spine, defects of bone and other aspects of bone. The early clinical application results of tantalum in bone
Giulio Maccauro et al.
Recent patents on biotechnology, 3(3), 157-165 (2009-06-24)
Tantalum is obtained from the minerals colombite, tantalite and euxenite. It is greyish silver, heavy and very hard. Tantalum does not react with body fluids and is used to make surgical equipment. Tantalum also does not irritate the body and

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.