131326

Sigma-Aldrich

Pentachlorobenzene

96%

Sinonimo/i:

1,2,3,4,5-Pentachlorobenzene

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula condensata:
HC6Cl5
Numero CAS:
Peso molecolare:
250.34
Beilstein:
1911550
Numero CE:
Numero MDL:
Codice UNSPSC:
12352100
ID PubChem:
NACRES:
NA.22

Livello qualitativo

Saggio

96%

Stato

solid

P. ebollizione

275-277 °C (lit.)

Punto di fusione

84-87 °C (lit.)

Densità

1.609 g/mL at 25 °C (lit.)

Gruppo funzionale

chloro

Stringa SMILE

Clc1cc(Cl)c(Cl)c(Cl)c1Cl

InChI

1S/C6HCl5/c7-2-1-3(8)5(10)6(11)4(2)9/h1H
CEOCDNVZRAIOQZ-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Categorie correlate

Descrizione generale

Pentachlorobenzene was determined in the water samples by packed sorbent (MEPS) coupled directly to programmed temperature vaporizer-gas chromatography-mass spectrometry.

Applicazioni

Pentachlorobenzene was used to prepare tetrachlorobenzene by photolysis.

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Flam. Sol. 1

Codice della classe di stoccaggio

4.1B - Flammable solid hazardous materials

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

Not applicable

Punto d’infiammabilità (°C)

Not applicable


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Slide 1 of 2

1 of 2

Synthesis of bridgehead fluorides by fluorodeiodination.
Della EW and Head NJ. et al.
The Journal of Organic Chemistry, 57(10), 2850-2855 (1992)
Gloria Grueiro Noche et al.
Analytical and bioanalytical chemistry, 405(21), 6739-6748 (2013-06-20)
A fully automated method consisting of microextraction by packed sorbent (MEPS) coupled directly to programmed temperature vaporizer-gas chromatography-mass spectrometry (PTV-GC-MS) has been developed to determine the 12 chlorobenzene congeners (chlorobenzene; 1,2-, 1,3-, and 1,4-dichlorobenzene; 1,2,3-, 1,2,4-, and 1,3,5-trichlorobenzene; 1,2,3,4-, 1,2,3,5-
Ian John Allan et al.
Journal of environmental monitoring : JEM, 13(9), 2420-2426 (2011-07-27)
Thirty two polychlorinated biphenyl congeners (PCBs), hexachlorobenzene (HCB) and pentachlorobenzene (PeCB) were analysed in passive sampler extracts from surface water-exposed semipermeable membrane devices (SPMDs) and in bed sediment samples from a small urban watercourse, the River Alna (Oslo, Norway). Performance
Lance J Schuler et al.
Chemosphere, 77(3), 399-403 (2009-08-14)
Nonpolar organic chemicals such as polycyclic aromatic hydrocarbons and chlorobenzenes are expected to act additively when exposed as a mixture. The present study examined the toxicity of fluoranthene (FLU) and pentachlorobenzene (PCBz) individually and in a binary mixture using the
N Martí et al.
Marine pollution bulletin, 62(3), 615-625 (2011-02-08)
A comprehensive study aimed at evaluating the occurrence, significance of concentrations and spatial distribution of priority pollutants (PPs) along the Comunidad Valenciana coastal waters (Spain) was carried out in order to fulfil the European Water Framework Directive (WFD). Additionally, PP

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.