Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

PHR1490

Supelco

Monoethanolamine

Pharmaceutical Secondary Standard; Certified Reference Material

Synonyme(s) :

2-Aminoéthanol, Alcool 2-aminoéthylique

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
NH2CH2CH2OH
Numéro CAS:
Poids moléculaire :
61.08
Numéro Beilstein :
505944
Numéro CE :
Numéro MDL:
Code UNSPSC :
41116107
Nomenclature NACRES :
NA.24

Qualité

certified reference material
pharmaceutical secondary standard

Niveau de qualité

Agence

traceable to Ph. Eur. Y0001184
traceable to USP 1445925

Densité de vapeur

2.1 (vs air)

Pression de vapeur

0.2 mmHg ( 20 °C)

Description

Pharmaceutical Secondary Standard; Certified Reference Material

Famille d'API

ethanolamine

CofA (certificat d'analyse)

current certificate can be downloaded

Température d'inflammation spontanée

1436 °F

Limite d'explosivité

17 %

Conditionnement

pkg of 1 mL

Technique(s)

HPLC: suitable
gas chromatography (GC): suitable

Indice de réfraction

n20/D 1.454 (lit.)

Point d'ébullition

170 °C (lit.)
69-70 °C/10 mmHg

Pf

10-11 °C (lit.)

Densité

1.012 g/mL at 25 °C (lit.)

Application(s)

pharmaceutical (small molecule)

Format

neat

Température de stockage

2-30°C

Chaîne SMILES 

NCCO

InChI

1S/C2H7NO/c3-1-2-4/h4H,1-3H2

Clé InChI

HZAXFHJVJLSVMW-UHFFFAOYSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards. Monoethanolamine is majorly used in pharmaceutical formulations in the buffer systems, and emulsion preparations. It can also be used as a solvent for fats and oils and to synthesize many salts having therapeutic essence.

Application

Monoethanolamine may be used as a pharmaceutical reference standard for the quantification of the analyte in pharmaceutical formulations and cosmetic products by chromatography.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Remarque sur l'analyse

These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.

Autres remarques

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Note de bas de page

To see an example of a Certificate of Analysis for this material enter LRAC2076 in the Documents slot below. This is an example certificate only and may not be the lot that you receive.

Produits recommandés

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Produit(s) apparenté(s)

Pictogrammes

CorrosionExclamation mark

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Dam. 1 - Skin Corr. 1B - STOT SE 3

Organes cibles

Respiratory system

Code de la classe de stockage

8A - Combustible corrosive hazardous materials

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

195.8 °F - Pensky-Martens closed cup

Point d'éclair (°C)

91 °C - Pensky-Martens closed cup


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Les clients ont également consulté

Simultaneous analysis of mono-, di-, and tri-ethanolamine in cosmetic products using liquid chromatography coupled tandem mass spectrometry
Shin KO and Lee YM
Archives of Pharmacal Research, 39(1), 66-72 (2016)
Handbook of Pharmaceutical Excipients (2009)
Monoethanolamine
USP42-NF37
United States Pharmacopeia/National Formulary, 31(5), 5836-5836 (2013)

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique