Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

KTGRA10FF1

Millipore

Aervent® 0,2 µm, capsule Opticap® XL

Opticap® XL 10, pore size 0.2 μm, hydrophobic, 19 mm (3/4 in.) inlet/outlet sanitary flange, sterilization compatible with autoclavable, non-sterile

Synonyme(s) :

Aervent KTGR Opticap XL10 Capsule

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
23151806
eCl@ss :
32031690

Matériaux

PTFE
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal

Niveau de qualité

Stérilité

non-sterile

Mode de stérilisation compatible

autoclavable compatible

Gamme de produits

Opticap® XL 10

Caractéristiques

hydrophobic

Fabricant/nom de marque

Aervent®

Paramètres

≤24 mL/min air diffusion at 965 mbar (14 psig) and 23 °C (in 70/30%IPA/water)
≤24 mL/min nitrogen diffusion at 970 mbar (14 psig) and 23 °C (in 70/30% IPA/water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C (Forward)
2.8 bar max. inlet pressure (40 psi) at 60 °C (Forward)
25 °C max. inlet temp.
4.1 bar max. differential pressure (60 psid) (Reverse; intermittent)
4.1 bar max. inlet pressure (60 psi) (Reverse; Intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C (Forward)
80 psig max. inlet pressure

Technique(s)

gas filtration: suitable

Longueur

13.2 in.

Largeur

4.2 in.

Longueur nominale des cartouches

10 in. (25 cm)

Diamètre

10.7 cm (4.2 in.)

Surface de filtration

0.65 m2

Diam. du raccord d'entrée

3/4 in.

Largeur, de l'entrée à la sortie

33.0 cm (13.0 in.)

Diam. du raccord de sortie

3/4 in.

Impuretés

<0.25 EU/mL USP bacterial endotoxins (LAL test, aqueous extraction)

Extractibles par gravimétrie

≤45 mg/cartridge

Matrice

Aervent®

Dimension de pores

0.2 μm pore size

Entrée

sample type gas

Point de bulle

≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C

Raccords

19 mm (3/4 in.) inlet/outlet sanitary flange

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

Device Configuration: Capsule

Conditionnement

Double Easy-Open bag

Qualité

Retains Brevundimonas diminuta liquid aerosol for 21 days at a minimum challenge of 10⁷ CFU/cm²

Notes préparatoires

Sterilization Method
30 autoclave cycles of 30 min @ 135 °C
This product was manufactured with a PTFE membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Remarque sur l'analyse

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Gravimetric Extractables: after 24 hours in a 70/30% IPA/water mixture at controlled room temperature
HydroCorr: ≤0.75 mL/min @ 2.6 bar (38 psig) per sample

Autres remarques

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Informations légales

AERVENT is a registered trademark of Merck KGaA, Darmstadt, Germany
ASTM is a registered trademark of American Society for Testing and Materials
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Clause de non-responsabilité

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 2014/68/EU of 15 May 2014. This product has been classified under Article 4 § 3 of the Directive 2014/68/EU. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 4 § 3 of the Directive 2014/68/EU, this product does not bear the CE mark.

Vous ne trouvez pas le bon produit ?  

Essayez notre Outil de sélection de produits.


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique