Accéder au contenu
Merck
Toutes les photos(4)

Key Documents

HCCBP1MAG-58K

Millipore

MILLIPLEX® Human Circulating Cancer Biomarker Magnetic Bead Panel - Cancer Multiplex Assay

Circulating Cancer Biomarker Bead-Based Multiplex Assays using the Luminex technology enables the simultaneous analysis of multiple oncology biomarkers in various tumor types in human serum, plasma and cell culture samples.

Synonyme(s) :

human cancer biomarker immunoassay panel, luminex human circulating cancer biomarkers multiplex assay, millipore human circulating cancer biomarkers multiplex kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
12161503
eCl@ss :
32161000

Niveau de qualité

Espèces réactives

human

Fabricant/nom de marque

Milliplex®

assay range

accuracy: 35-108%
standard curve range: 0.09-67 mU/mL
(β-HCG)

standard curve range: 0.7-500 pg/mL
(IL-6)

standard curve range: 1.3-1000 pg/mL
(IL-8, TNFα)

standard curve range: 2.7-2000 pg/mL
(TRAIL, TGF-α)

standard curve range: 6.9-5000 pg/mL
(SCF)

Technique(s)

multiplexing: suitable

Méthode de détection

fluorometric (Luminex xMAP)

Conditions d'expédition

wet ice

Description générale

Circulating cancer biomarkers give insight beyond intracellular oncogenesis and into how the body responds to the presence of a tumor, the dysregulation of homeostasis, and the relationship between a tumor and its environment. Multianalyte panels have become essential tools that enable researchers to measure cancer biomarkers simultaneously, teasing out these relationships and applying them to understand tumor biology.

MILLIPLEX® Circulating Cancer Biomarker Panel 1 is a 25-plex kit that can be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and tissue/cell lysate and culture supernatant samples: AFP, CA125, CA15-3, CA19-9, CEA, CYFRA21-1, sFas, sFasL, FGF2, β-HCG, HE4, HGF, IL-6, IL-8, Leptin, MIF, Osteopontin, Prolactin, PSA (free), PSA (total), SCF, TGFα, TNFα, TRAIL and VEGF. Note that certain biomarkers are tumor specific, such as PSA, while others, such as IL-8, have been detected in many cancers. PSA (free) and PSA (total) cannot be plexed together. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Circulating Cancer

Spécificité

Cross Reactivty
Cross-reactivity between the antibodies and any of the other analytes in this panel is non-detectable or negligible.

Application

  • Analytes: α-Fetoprotein (AFP), CA125, CA15-3, CA19-9, CEA, CYFRA21-1, sFas (TNFRSF6), sFasL, FGF-2 (FGF-basic), β-HCG (HCGβ), HE4, HGF, IL-6, IL-8 (CXCL8), Leptin, MIF, Osteopontin (OPN), Prolactin, PSA (free)*, PSA (total)*, SCF, TGFα, TNFα, TRAIL (TNFSF10), VEGF.
  • Note: Total PSA and Free PSA cannot be plexed together
  • Recommended Sample Type: Human serum, plasma or tissue/cell culture supernatants or lysates
  • Recommended Sample Dilution: 25 μL per well of 1:6 diluted plasma or serum, or 25 μL cell culture psaesaa sample undiluted or diluted in appropriate control medium
  • Assay Run Time: Overnight (16-18 hr) at 2-8°C
  • Research Category: Cancer

Caractéristiques et avantages

Design your multiplex kit by choosing available analytes within this panel.

Conditionnement

Everything you need in a single kit.

Composants

Human Circulating Cancer Biomarker Panel 1 Standard (HCC-8058)

Human Circulating Cancer Biomarker Panel 1 Quality Controls 1 and 2 (HCC-6058)

Serum Matrix (HCP-SM)
Note: Contains 0.08% Sodium Azide

Set of one 96-Well Plate with 2 Sealers (MAG-PLATE)

Assay Buffer (L-AB)
Note: Contains 0.08% Sodium Azide

10X Wash Buffer (L-WB)
Note: Contains 0.05% Proclin

Human Circulating Cancer Biomarker Panel 1 Detection Antibodies (HCC-1058 or HCC-1058-2)

Streptavidin-Phycoerythrin (L-SAPE 4)

Bead Diluent (LBD-4)

Stockage et stabilité

Recommended storage for kit components is 2 - 8°C.

Autres remarques

Please note: Total PSA and Free PSA cannot be plexed together.
Sensitivity: Refer to kit protocol for sensitivities of individual biomarkers.

Informations légales

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Organes cibles

Respiratory Tract

Code de la classe de stockage

10 - Combustible liquids

Classe de danger pour l'eau (WGK)

WGK 3


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique