Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

CBA024

Sigma-Aldrich

InnoZyme Myeloperoxidase Activity Kit

Synonyme(s) :

InnoZyme MPO Activity Kit

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41116133
Nomenclature NACRES :
NA.77

Utilisation

sufficient for 96 tests

Niveau de qualité

Espèces réactives

human

Conditionnement

pkg of 1 96-well plate(s)

Fabricant/nom de marque

Calbiochem®

Conditions de stockage

OK to freeze
avoid repeated freeze/thaw cycles
protect from light

assay range

sensitivity: 330 pg/mL
standard curve range: 5-100 ng/mL

Entrée

sample type serum
sample type cerebrospinal fluid (CSF)
sample type cell lysate

Méthode de détection

colorimetric

Conditions d'expédition

wet ice

Température de stockage

−20°C

Description générale

The InnoZyme Myeloperoxidase Activity Kit is a specific and sensitive assay designed to measure myeloperoxidase activity and to screen enzyme inhibitors. The assay uses a polyclonal antibody specific for human MPO immobilized on a 96-well plate to specifically capture the enzyme. Activity of captured myeloperoxidase is measured using a detection reagent that includes TMB and hydrogen peroxide. Following color development, the reaction is stopped with sulfuric acid and the absorbance of the oxidized TMB is detected at 450 nm.

Composants

Anti-MPO Coated 96-Well Plate, MPO Standard, TMB, Hydrogen Peroxide, Assay Buffer, Sample Buffer, Stop Solution, Plate Sealers, and a user protocol.

Avertissement

Toxicity: Multiple Toxicity Values, refer to MSDS (O)

Caractéristiques

Assay Time: 2 h

Principe

The Calbiochem InnoZyme Myeloperoxidase Activity Kit is designed to measure human myeloperoxidase activity in cell lysates and biological samples and to screen enzyme inhibitors.

Notes préparatoires

All reagents necessary to perform the assay are supplied with the kit. Equilibrate all reagents to room temperature (15-25°C) just prior to use.Sample Buffer (1X): Dilute Sample Buffer 1:20 by adding 25 ml Sample Buffer to 475 ml dH2O. Myeloperoxidase Standard (1g/ml): Dilute the Myeloperoxidase Standard 1:100 by adding 5 l Myeloperoxidase Standard to 495 l chilled Sample Buffer (1X) obtain a concentration of 1 g/ml. Maintain the diluted Myeloperoxidase Standard (1 g/ml) on ice. Note: Following initial thaw the Myeloperoxidase Standard should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.<div class="Bio_doc_image">
Table 1: Myeloperoxidase Standard Dilutions
Prepare Myeloperoxidase Standard dilutions in the range of 5-100 ng/ml using the above guidelines.
</div>Hydrogen Peroxide (0.3%): Dilute the Hydrogen Peroxide (30%) 1:100 by adding 5 l Hydrogen Peroxide (30%) to 495 l chilled dH2O. Note: A total of 40 l is required to cover the entire Coated 96-Well Plate. If the entire plate is not to be used at one time, prepare fresh Hydrogen Peroxide (0.3%) each time the assay is performed. Following initial thaw the Hydrogen Peroxide should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.TMB Detection Reagent: Note: The desired amount of TMB Detection Reagent should be prepared fresh, just prior to use. To prepare TMB Detection Reagent, mix the following components:
  • 7.16 ml dH2O
  • 2.00 ml Assay Buffer
  • 0.80 ml TMB
  • 40 l H2O2(0.3%)

Vortex gently 3 X 3 sTo prepare TMB Detection Reagent for a variable number of strips, use the following guidelines: <div class="Bio_doc_image">Table 2: Preparation of TMB Detection Reagent
To prepare TMB Detection Reagent for a variable number of strips, use the above guidelines.
</div>
Dilute samples with Sample Buffer (1X) as needed. Note: If sample dilution is not required for sensitivity reasons, prepare the sample by adding 475 µl sample to 25 µl 20X Sample Buffer to ensure appropriate pH for the first incubation.

Stockage et stabilité

Upon arrival, store the unopened kit at -20°C. All kit components, once opened, can be stored for up to 3 months under the following conditions:



Store at 4°C: TMB, Anti-MPO Coated 96-Well Plate, Assay Buffer, Stop Solution, and Sample Buffer

Store at -20°C: Myeloperoxidase Standard, and Hydrogen Peroxide



Note: Following initial use the Myeloperoxidase Standard and the Hydrogen Peroxide should be dispensed into aliquots and stored at -20°C. Avoid freeze/thaw cycles.

Remarque sur l'analyse

Positive Control
Human myeloperoxidase

Autres remarques

Due to the nature of the Hazardous Materials in this shipment, additional shipping charges may be applied to your order. Certain sizes may be exempt from the additional hazardous materials shipping charges. Please contact your local sales office for more information regarding these charges.
Weil, S.C., et al. 1988. Science 240, 790.
Winterbourn, C.C., et al. 2000. Curr. Opin. Hematol. 7, 53.
Brennan, M.L., et al. 2003. New Engl. J Med. 349, 1595.
Zheng, L., et al. 2004. J. Biol. Chem. in press
Vita, J.A., et al. 2004. Circulation, 110, 1134.

Informations légales

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogrammes

CorrosionExclamation mark

Mention d'avertissement

Danger

Mentions de danger

Classification des risques

Eye Dam. 1 - Met. Corr. 1 - Skin Irrit. 2 - Skin Sens. 1

Code de la classe de stockage

8A - Combustible corrosive hazardous materials


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Alessandro Trentini et al.
Inflammation research : official journal of the European Histamine Research Society ... [et al.], 63(5), 325-328 (2014-01-25)
We investigated the effect of balanced (BS) and unbalanced (UBS) solutions in the absence or presence of hydroxyethyl starch (HES) on neutrophil functionality, evaluating the release of matrix metalloproteinase (MMP)-9, myeloperoxidase (MPO), and MMP-8. Neutrophils were isolated by gradient centrifugation

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique