K-002
Ketamine hydrochloride solution
1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Produits recommandés
Qualité
certified reference material
Niveau de qualité
Forme
liquid
Caractéristiques
Snap-N-Spike®/Snap-N-Shoot®
Conditionnement
ampule of 1 mL
Fabricant/nom de marque
Cerilliant®
drug control
psicótropo (Spain)
Concentration
1.0 mg/mL in methanol (as free base)
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
forensics and toxicology
Format
single component solution
Température de stockage
−20°C
InChI
1S/C13H16ClNO.ClH/c1-15-13(9-5-4-8-12(13)16)10-6-2-3-7-11(10)14;/h2-3,6-7,15H,4-5,8-9H2,1H3;1H
Clé InChI
VCMGMSHEPQENPE-UHFFFAOYSA-N
Informations sur le gène
human ... GRIN1(2902) , GRIN2A(2903) , GRIN2B(2904) , GRIN2C(2905) , GRIN2D(2906) , GRIN3A(116443) , GRIN3B(116444)
Catégories apparentées
Description générale
Ketamine is a phencyclidine type of anaesthetic drug that blocks the N-methyl-d-aspartate (NMDA) receptors present on neurons. It is also an abused drug owing to its euphoric and hallucinogenic effects. The drug is also abused at clubs, raves, or parties for its noted hallucinogenic and dissociative properties and is prescribed by some doctors as an off-label treatment for depression.
Application
- Development of a chiral liquid chromatography-tandem mass spectrometric (LC-MS/MS) method to quantify enantiomers of ketamine and norketamine in plasma, brain, and cerebrospinal fluid samples obtained from mouse
- Multi-residue and non-destructive analysis of ketamine, methamphetamine, heroin, and cocaine by a near-infrared spectroscopic (NIR) method in seized drug samples
- Combined detection and estimation of ketamine, free methamphetamine, pethidine, and tramadol in human urine samples using dispersive liquid-liquid microextraction (DLLME) and gas chromatography-mass spectrometry (GC-MS)
- Electrochemical determination of ketamine in human urine samples using a metal-organic framework/graphene nanocomposite (MOFs@G) modified screen-printed electrode (SPE) after the UV polymerization of molecularly imprinted membranes on its surface
- Simultaneous analysis of ketamine, GHB, norketamine, phenobarbital, thiopental, zolpidem, zopiclone, and phenytoin in human urine samples by a LC-MS/MS procedure following a four-step liquid-liquid extraction of the samples
Caractéristiques et avantages
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Organes cibles
Eyes
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 2
Point d'éclair (°F)
49.5 °F - closed cup
Point d'éclair (°C)
9.7 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique