B-035
Buprenorphine glucuronide solution
100 μg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®
Synonyme(s) :
Buprenorphine-3-β-D-glucuronide solution
About This Item
Produits recommandés
Qualité
certified reference material
Niveau de qualité
Forme
liquid
Caractéristiques
SNAP-N-SPIKE®, SNAP-N-SHOOT®
Conditionnement
ampule of 1 mL
Fabricant/nom de marque
Cerilliant®
drug control
Narcotic Licence Schedule A (Switzerland)
Concentration
100 μg/mL in methanol
Technique(s)
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
Application(s)
clinical testing
Format
single component solution
Température de stockage
−20°C
Chaîne SMILES
CO[C@]12CC[C@@]3(C[C@@H]1[C@](C)(O)C(C)(C)C)[C@H]4Cc5ccc(O[C@@H]6O[C@@H]([C@@H](O)[C@H](O)[C@H]6O)C(O)=O)c7O[C@@H]2[C@]3(CCN4CC8CC8)c57
InChI
1S/C35H49NO10/c1-31(2,3)32(4,42)20-15-33-10-11-35(20,43-5)30-34(33)12-13-36(16-17-6-7-17)21(33)14-18-8-9-19(26(46-30)22(18)34)44-29-25(39)23(37)24(38)27(45-29)28(40)41/h8-9,17,20-21,23-25,27,29-30,37-39,42H,6-7,10-16H2,1-5H3,(H,40,41)/t20-,21-,23+,24+,25-,27+,29-,30-,32+,33-,34+,35-/m1/s1
Clé InChI
CZULHKGIAJASAA-WWIHBJMFSA-N
Description générale
Application
- Simplified processing and rapid quantification of buprenorphine, norbuprenorphine, and their conjugated metabolites in human plasma using UPLC-MS/MS: This study underscores the importance of buprenorphine glucuronide as a standard in pharmacokinetic research, facilitating accurate assessments of buprenorphine exposure during opioid use disorder treatment (Zhao et al., 2024).
- Quantitative Analysis of Buprenorphine, Norbuprenorphine, and Their Glucuronide Metabolites in Human Urine: Highlights the application of buprenorphine glucuronide in developing methods for analyzing opioid metabolites in urine, crucial for monitoring drug therapy and compliance in clinical settings (Gqamana et al., 2024).
- Interaction between buprenorphine and norbuprenorphine in neonatal opioid withdrawal syndrome: The research uses buprenorphine glucuronide to study drug interactions in treating neonatal opioid withdrawal, demonstrating its significance in neonatal pharmacological research and therapy optimization (Tobacyk et al., 2023).
Informations légales
Produit(s) apparenté(s)
Mention d'avertissement
Danger
Mentions de danger
Conseils de prudence
Classification des risques
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
Organes cibles
Eyes
Code de la classe de stockage
3 - Flammable liquids
Classe de danger pour l'eau (WGK)
WGK 1
Point d'éclair (°F)
49.5 °F - closed cup
Point d'éclair (°C)
9.7 °C - closed cup
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Protocoles
To optimize hydrolysis using β-glucuronidase, factors such as incubation time, temperature, hydrolysis pH, enzyme source, and enzyme concentration must be evaluated for each glucuronide metabolite to be analyzed.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique