Accéder au contenu
MilliporeSigma
Toutes les photos(1)

Key Documents

CRM69368

Supelco

Buprofezin

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule empirique (notation de Hill):
C16H23N3OS
Numéro CAS:
Poids moléculaire :
305.44
Numéro Beilstein :
8324923
Numéro MDL:
Code UNSPSC :
41116107
Nomenclature NACRES :
NA.24

Qualité

certified reference material
TraceCERT®

Niveau de qualité

Gamme de produits

TraceCERT®

Forme

solid

Durée de conservation

limited shelf life, expiry date on the label

Fabricant/nom de marque

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Chaîne SMILES 

CC(C)N1C(=O)N(CS\C1=N\C(C)(C)C)c2ccccc2

InChI

1S/C16H23N3OS/c1-12(2)19-14(17-16(3,4)5)21-11-18(15(19)20)13-9-7-6-8-10-13/h6-10,12H,11H2,1-5H3/b17-14+

Clé InChI

PRLVTUNWOQKEAI-SAPNQHFASA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com

Buprofezin― a thiadiazine insecticide, inhibits chitin synthesis and acts as a molting inhibitor and growth regulator. It is a broad spectrum and non-systemic insecticide, that gets activated by contact and ingestion. Buprofezin inhibits molting in insect larvae and nymphs, subsequently leading to their death. It is used against beetles, leafhoppers, plant hoppers, and whiteflies among other insects for a variety of crops, vegetables, and fruits.
Buprofezin is approved for use in the European Union as a plant protection agent in the market according to the Commission Directive 2011/6/EU of 20th January 2011 repealing the Council Directive 91/414/EEC. The maximum residue level (MRL) allowed for the presence of buprofezin in plant- and animal-based products is 0.01 mg/kg as per the EU Reg 2019/91.
Buprofezin has to be monitored in the Multiannual Control Program for Pesticides Residues (MACP), run within the EU and EFTA in/on products of plant origin.

Application

The certified reference material (CRM) is intended to be used as a calibrant for chromatography and other analytical techniques.
Buprofezin CRM may also find the following uses:

  • Development of a high-performance liquid chromatography-diode-array detector (HPLC-DAD) method for simultaneous analysis of buprofezin, dinobuton, and chlorothalonil in various biological, food, and environmental samples
  • Determining metolachlor and buprofezin in natural water samples by thermochemically-induced fluorescence derivatization (TIFD) method
  • To study the dissipation of acetamiprid and buprofezin in paddy grain, straw, and soil samples, in addition to their residue analysis by high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection
  • Multi-residue analysis of 42 pesticides in six marijuana samples by QuEChERS extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) determination
  • Quantification of 57 pesticide residues in tomato samples by liquid chromatography-electrospray ionization tandem mass spectrometry method
  • Simultaneous determination of 60 pesticide residues in various fruit and vegetable samples by using solid-phase extraction (SPE) for sample preparation and ultra-high-performance liquid chromatography/time-of-flight mass spectrometry (UHPLC/TOF-MS) for measurement

Produits recommandés

Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Informations légales

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogrammes

Health hazardEnvironment

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Aquatic Acute 1 - Aquatic Chronic 1 - STOT RE 2

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique