1.50404

Supelco

Chromolith® CapRod® HighResolution RP-18 endcapped Capillary Columns

L × I.D. 150 mm x 0.1 mm capillary column

Synonyme(s) :

Chromolith® CapRod® RP-18 endcapped HR 150-0.1 capillary column

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41115709

Matériaux

PEEK column

Niveau de qualité

Agence

suitable for USP L1

Gamme de produits

Chromolith®

Caractéristiques

endcapped

Conditionnement

1 ea of

Ampleur du marquage

18% Carbon loading

Paramètres

218 bar pressure

Technique(s)

HPLC: suitable
LC/MS: suitable (Capillary LC)
mass spectrometry (MS): suitable (High)

Colonne, L × D.I.

15 cm × 0.1 mm

Matrice

monolithic silica

Groupe de la matrice active

C18 bonding phase

Dimension de pores

1 μm macroporosity
13 nm mesoporosity

operating pH range

2-7.5

Technique de séparation

reversed phase

Température de stockage

no temp limit

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

A Chromolith® CapRod® capillary column combines the speed of monolithic silica technology with the sensitivity of nano-LC. This enables superior productivity for high throughput, highly sensitive proteomics-LC applications.
Compared to particulate capillary columns, Chromolith® CapRod® capillaries demonstrate better performance with optimal resolution (narrow peak widths), increased productivity (higher sample throughput), and extended column lifetime. Furthermore, column length is less limited than with any other type of column. The capillaries can even be slightly bent to fit any LC configuration or instrument.
Chromolith® CapRod® columns are designed to work with various nano or capillary-LC systems. This provides the highest efficiency and performance when coupled to mass spectrometers, both on-line (ESI, nanospray) and off-line (MALDI).

Why choose Chromolith® CapRod® capillary columns?
—Higher flow rates than particle-packed capillary columns
—Columns at low pressure
—Long column lifetime
—Robust and easy handling
—Flow rates from 0.1–200 μL/min ensure ideal compatibility with LC/MS systems, with both ESI and APCI interfaces

Chromolith® CapRod® HighResolution (HR) RP-18 endcapped provides higher separation efficiency and can be operated at significantly higher flow rates without loss of performance. The typical flow rate for this 150-0.1 capillary column ranges from 0.1 μL/min to 0.4 μL/min.

Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns

Informations légales

Chromolith is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique